EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Load‐slip response and reuse potential of shield anchor bolt connectors in steel‐timber composite floors

Dan V. Bompa, Mark Kariuki, Thabang Ntanda, Viorel Ungureanu, Ahmed Y. Elghazouli

ce/papers · 2026-09 · 9 (2-3) · 1236-1241

DOI: 10.1002/cepa.70439 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Dan V. Bompa und 4 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper investigates the structural performance and reuse potential of shield anchor bolts as mechanical shear connectors in steel‐timber floors. A series of monotonic and cyclic push‐out tests, using a proposed reuse testing protocol, were conducted on cross‐laminated timber panels and steel sections connected by 10 mm and 12 mm diameter connectors. The results show that shield anchor bolts provide adequate stiffness, strength and deformation capacity, superior to other dry shear connection systems, largely due to the sleeve. Cyclic testing confirmed that connection stiffness increases with each cycle, following a logarithmic trend, and that the stiffness measured after reassembly was approximately 31% higher than that from the initial loading cycle. The reassembly peak load was within ranges similar to those of the monotonic benchmark tests. The results indicate that the shield anchor bolts exhibit superior reusability, with minimal damage to the connection components compared to other practical systems. A modified separation damage index was developed to quantify the circularity of these shear connectors. The findings suggest that dry, mechanically fastened shear connections, such as those using shield anchors, are suitable for reuse applications.

Zitieren

APA

Bompa, D. V., Kariuki, M., Ntanda, T., Ungureanu, V., & Elghazouli, A. Y. (2026). Load‐slip response and reuse potential of shield anchor bolt connectors in steel‐timber composite floors. ce/papers, 9(2-3), 1236-1241. https://doi.org/10.1002/cepa.70439

Vancouver

Bompa DV, Kariuki M, Ntanda T, Ungureanu V, Elghazouli AY. Load‐slip response and reuse potential of shield anchor bolt connectors in steel‐timber composite floors. ce/papers. 2026;9(2-3):1236-1241. doi:10.1002/cepa.70439

BibTeX
@article{Bompa2026,
  author = {Bompa, Dan V. and Kariuki, Mark and Ntanda, Thabang and Ungureanu, Viorel and Elghazouli, Ahmed Y.},
  title = {Load‐slip response and reuse potential of shield anchor bolt connectors in steel‐timber composite floors},
  journal = {ce/papers},
  year = {2026},
  volume = {9},
  number = {2-3},
  pages = {1236--1241},
  doi = {10.1002/cepa.70439}
}
Kostenlos starten →