On the Shear Force Capacity of Sinusoidal Corrugated Web Girders
ce/papers · 2026-09 · 9 (2-3) · 2932-2937
DOI: 10.1002/cepa.70436 ↗Kurz gefasst
Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Gábor Hajdú und 2 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
According to EN 1993‐1‐5:2024, the shear resistance of plate girders with flat webs is determined by considering the contribution of both the web and a defined portion of the flanges. However, in the design of corrugated web beams the flange contribution is neglected, leading to a fundamental difference in the assessment of shear capacity. An extensive numerical parameter study is conducted to evaluate the influence of key geometric parameters, web and flange dimensions, corrugation amplitude, wavelength, and beam length, on the shear resistance. The results provide a clearer understanding of the interaction between web geometry and flange contribution to support the assessment of their relative influence on shear resistance. The results may support future refinements of design rules for sinusoidal corrugated beams within the Eurocode framework. In addition, conditions are specified for beams where local web buckling can be disregarded.
Zitieren
APA
Hajdú, G., Pasternak, H., & Robra, J. (2026). On the Shear Force Capacity of Sinusoidal Corrugated Web Girders. ce/papers, 9(2-3), 2932-2937. https://doi.org/10.1002/cepa.70436
Vancouver
Hajdú G, Pasternak H, Robra J. On the Shear Force Capacity of Sinusoidal Corrugated Web Girders. ce/papers. 2026;9(2-3):2932-2937. doi:10.1002/cepa.70436
BibTeX
@article{Hajd2026,
author = {Hajdú, Gábor and Pasternak, Hartmut and Robra, Jörgen},
title = {On the Shear Force Capacity of Sinusoidal Corrugated Web Girders},
journal = {ce/papers},
year = {2026},
volume = {9},
number = {2-3},
pages = {2932--2937},
doi = {10.1002/cepa.70436}
}
EUVIMED