Experimental Study of Cold‐Formed Steel Floor Joists under Serviceability Limit State

Ruilin Zhang, Cao Hung Pham, Paul Jones, Trevor Clayton, Mark Eckermann

ce/papers · 2026-09 · 9 (2-3) · 2259-2264

DOI: 10.1002/cepa.70427 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Ruilin Zhang und 4 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cold‐formed steel (CFS) floor joists are increasingly utilised in mid‐rise building construction owing to their high strength‐to‐weight ratio, fabrication efficiency, and ease of installation. These floor joists are typically configured as truss systems with top and bottom chords fabricated from unlipped channels, and diagonal web channels fabricated from lipped and stiffened channels spanning between the chords. The chords and webs are connected at their flanges using screwed connections with pre‐punched dimple holes, and all the joist members are oriented to bend about their asymmetric axis. An experimental program was recently performed at the University of Sydney to investigate the serviceability performance of CFS floor joists. A test rig was designed to apply uniform forces at each joint connection of the top chord. This experimental program examined warren truss configurations with chord width of 70 mm and member thicknesses of 0.75 mm and 1 mm. Load–displacement responses in the serviceability range were measured, and flexural stiffness values were derived. Analytical equations were subsequently formulated to estimate the elastic stiffnesses and predict mid‐span deflections of the joists. Comparison between experimental and analytical results showed close agreement, confirming that the proposed equations reliably capture the stiffness characteristics of CFS floor joists under serviceability limit states.

Zitieren

APA

Zhang, R., Pham, C. H., Jones, P., Clayton, T., & Eckermann, M. (2026). Experimental Study of Cold‐Formed Steel Floor Joists under Serviceability Limit State. ce/papers, 9(2-3), 2259-2264. https://doi.org/10.1002/cepa.70427

Vancouver

Zhang R, Pham CH, Jones P, Clayton T, Eckermann M. Experimental Study of Cold‐Formed Steel Floor Joists under Serviceability Limit State. ce/papers. 2026;9(2-3):2259-2264. doi:10.1002/cepa.70427

BibTeX
@article{Zhang2026,
  author = {Zhang, Ruilin and Pham, Cao Hung and Jones, Paul and Clayton, Trevor and Eckermann, Mark},
  title = {Experimental Study of Cold‐Formed Steel Floor Joists under Serviceability Limit State},
  journal = {ce/papers},
  year = {2026},
  volume = {9},
  number = {2-3},
  pages = {2259--2264},
  doi = {10.1002/cepa.70427}
}
Kostenlos starten →