EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application of reversible friction dampers to beam‐to‐column joints with CFSTs

Sabatino Di Benedetto, Ciro Esposito, Antonella Bianca Francavilla, Massimo Latour, Gianvittorio Rizzano

ce/papers · 2026-09 · 9 (2-3) · 1566-1571

DOI: 10.1002/cepa.70411 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Sabatino Di Benedetto und 4 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Current building codes prescribe seismic design approaches that ensure safety by allowing structures to dissipate energy through extensive inelastic deformations. While effective in preventing collapse, this philosophy accepts damage, which results in high repair costs and long periods during which the building cannot be used. To overcome these drawbacks, new structural solutions have been developed with the aim of improving seismic resilience while limiting damage. Among these, systems using friction devices at beam‐to‐column connections have received increasing attention. Such devices dissipate seismic energy without compromising the main structural members and can be restored with straightforward maintenance, such as bolt re‐tightening or replacement of friction plates. Well‐known examples are the Sliding Hinge Joint and the FREEDAM connection. However, these technologies have been studied mainly for joints involving double‐tee members, whereas their application to hollow section columns has not yet been explored. The present work aims at addressing this gap by proposing an innovative steel friction damper for connections between IPE beams and Concrete Filled Steel Tubular (CFST) columns. The system consists of transverse and longitudinal plates that pass through laser‐cut openings in the composite column and are welded to it. The transverse plate is bolted to the beam flange, while the longitudinal plate is connected to L‐stubs and friction plates. The intended behaviour is that, once the applied actions reach the slip capacity of the friction device, the connection rotates around a centre of rotation located at the transverse plate close to the column, with a constant bending moment. To assess the performance of this solution, the present study combines experimental testing on a beam‐to‐column sub‐assembly, numerical simulations calibrated against the test results and an analytical formulation for predicting the flexural response of the connection.

Zitieren

APA

Benedetto, S. D., Esposito, C., Francavilla, A. B., Latour, M., & Rizzano, G. (2026). Application of reversible friction dampers to beam‐to‐column joints with CFSTs. ce/papers, 9(2-3), 1566-1571. https://doi.org/10.1002/cepa.70411

Vancouver

Benedetto SD, Esposito C, Francavilla AB, Latour M, Rizzano G. Application of reversible friction dampers to beam‐to‐column joints with CFSTs. ce/papers. 2026;9(2-3):1566-1571. doi:10.1002/cepa.70411

BibTeX
@article{Benedetto2026,
  author = {Benedetto, Sabatino Di and Esposito, Ciro and Francavilla, Antonella Bianca and Latour, Massimo and Rizzano, Gianvittorio},
  title = {Application of reversible friction dampers to beam‐to‐column joints with CFSTs},
  journal = {ce/papers},
  year = {2026},
  volume = {9},
  number = {2-3},
  pages = {1566--1571},
  doi = {10.1002/cepa.70411}
}
Kostenlos starten →