Fire resistance of trapezoidal sheeting connected to a concrete beam
ce/papers · 2026-09 · 9 (2-3) · 2479-2482
DOI: 10.1002/cepa.70383 ↗Kurz gefasst
Fachartikel in der Zeitschrift ce/papers, online erschienen am 14.09.2026. Verfasst von Aleš Chovanec und 2 weiteren Autor:innen. Die Arbeit nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Cold‐formed steel trapezoidal sheeting bending resistance degrades significantly in fire due to the small thickness of the profiles. The response can subsequently transition to catenary action, which develops only with sufficient restraint from fasteners. Fasteners therefore often govern the fire performance. In the presented study, connection tests at both normal and elevated temperature are conducted using steel anchor into reinforcement concrete. Several tests were conducted for temperature 20 and 700 °C and sheet thickness 0.75 and 1.5 mm. This paper also describes a large‐scale fire test of a lightweight roof with trapezoidal sheeting. Fastening with steel anchors into reinforced concrete supports was used. Fire test resulted in a failure of the sheeting connection and concrete support.
Zitieren
APA
Chovanec, A., Jandera, M., & Nuno, L. (2026). Fire resistance of trapezoidal sheeting connected to a concrete beam. ce/papers, 9(2-3), 2479-2482. https://doi.org/10.1002/cepa.70383
Vancouver
Chovanec A, Jandera M, Nuno L. Fire resistance of trapezoidal sheeting connected to a concrete beam. ce/papers. 2026;9(2-3):2479-2482. doi:10.1002/cepa.70383
BibTeX
@article{Chovanec2026,
author = {Chovanec, Aleš and Jandera, Michal and Nuno, Lopes},
title = {Fire resistance of trapezoidal sheeting connected to a concrete beam},
journal = {ce/papers},
year = {2026},
volume = {9},
number = {2-3},
pages = {2479--2482},
doi = {10.1002/cepa.70383}
}