Fachartikel in der Zeitschrift Journal of Chemometrics, online erschienen am 24.03.2026. Verfasst von Klaus Neymeyr und 4 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Peak group analysis (PGA), an MCR algorithm, has proven to be very successful in extracting pure component spectra and concentration profiles from IR and Raman spectral data when investigating carbonylation reactions with transition metal catalysts. In this field of study, mixture spectra typically exhibit high spectral selectivity, meaning certain peaks belong exclusively to a single chemical species. Under this condition, PGA can extract the associated pure component spectrum from the mixture spectra, and there is no factor ambiguity in these profiles. Here, we present a short mathematical proof of this remarkable PGA property.
Zitieren
APA
Neymeyr, K., Kubis, C., Prestin, L., Franke, R., & Sawall, M. (2026). Why Is the Peak Group Analysis So Effective for IR Spectra Analysis?. Journal of Chemometrics, 40(4). https://doi.org/10.1002/cem.70121
Vancouver
Neymeyr K, Kubis C, Prestin L, Franke R, Sawall M. Why Is the Peak Group Analysis So Effective for IR Spectra Analysis?. Journal of Chemometrics. 2026;40(4). doi:10.1002/cem.70121
BibTeX
@article{Neymeyr2026,
author = {Neymeyr, Klaus and Kubis, Christoph and Prestin, Lukas and Franke, Robert and Sawall, Mathias},
title = {Why Is the Peak Group Analysis So Effective for IR Spectra Analysis?},
journal = {Journal of Chemometrics},
year = {2026},
volume = {40},
number = {4},
doi = {10.1002/cem.70121}
}
EUVIMED