RD‐PMA: A Rigid‐Deformable Point‐Matching Algorithm for Two‐Dimensional Calibration of GC‐IMS
Journal of Chemometrics · 2026-02 · 40 (2)
DOI: 10.1002/cem.70106 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chemometrics, online erschienen am 17.02.2026. Verfasst von Shujuan Liu und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Gas chromatography‐ion mobility spectrometry (GC‐IMS) is a powerful analytical technique for characterizing volatile organic compounds (VOCs). However, variability in retention and drift times frequently complicates peak alignment and downstream analyses. To address this challenge, we introduce RD‐PMA, a Rigid‐Deformable Point‐Matching Algorithm derived from and extending an established point‐set registration framework. RD‐PMA is specifically designed for GC‐IMS data and incorporates dimension‐dependent modeling, where rigid translation is applied in the drift‐time dimension and nonlinear deformation is employed in the retention‐time dimension. Robustness is further enhanced through an iterative outlier‐removal procedure. Extensive evaluations across multiple GC‐IMS datasets, including both homogeneous and heterogeneous conditions, as well as same‐parameter and different‐parameter scenarios, demonstrate that RD‐PMA consistently outperforms conventional alignment approaches, such as internal reference‐based shifting and other point‐matching methods. The algorithm preserves structural consistency while delivering high alignment accuracy and resilience to noise and parameter variability. Collectively, these findings establish RD‐PMA as a reliable and scalable solution for GC‐IMS peak alignment, with broad applicability to large‐scale VOC profiling in chemometrics, food science, and clinical research.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Liu, S., Zhou, D., Mu, S., Jia, J., Gao, X., & He, X. (2026). RD‐PMA: A Rigid‐Deformable Point‐Matching Algorithm for Two‐Dimensional Calibration of GC‐IMS. Journal of Chemometrics, 40(2). https://doi.org/10.1002/cem.70106
Vancouver
Liu S, Zhou D, Mu S, Jia J, Gao X, He X. RD‐PMA: A Rigid‐Deformable Point‐Matching Algorithm for Two‐Dimensional Calibration of GC‐IMS. Journal of Chemometrics. 2026;40(2). doi:10.1002/cem.70106
BibTeX
@article{Liu2026,
author = {Liu, Shujuan and Zhou, Di and Mu, Shilong and Jia, Jian and Gao, Xiaoguang and He, Xiuli},
title = {RD‐PMA: A Rigid‐Deformable Point‐Matching Algorithm for Two‐Dimensional Calibration of GC‐IMS},
journal = {Journal of Chemometrics},
year = {2026},
volume = {40},
number = {2},
doi = {10.1002/cem.70106}
}