EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Chronocoulometric Quantum Dot Aptasensor for SARS‐CoV‐2 Nucleocapsid Protein Biomarker

Nelia A. Sanga, Marlon Oranzie, Zandile Leve, Kaylin C. Januarie, Kefilwe V. Mokwebo, Onyinyechi V. Uhuo, Natasha Ross, Samantha F. Douman, Keagan Pokpas, Emmanuel I. Iwuoha

ChemElectroChem · 15.07.2024 · 11 (14)

DOI: 10.1002/celc.202400118 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ChemElectroChem, online erschienen am 24.06.2024. Verfasst von Nelia A. Sanga und 9 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For the first time, a novel mercaptosuccinic acid‐capped tungsten telluride quantum dot (MSA‐WTe 3 ‐QD)‐based electrochemical aptasensor was designed for the determination of SARS‐CoV‐2 N‐protein in synthetic human serum, plasma and urine. The MSA‐WTe 3 ‐QD which exhibited spherical morphology and an average diameter of 3.56 nm were synthesized through a bottom‐up approach. The aptasensor was prepared by firstly immobilizing MSA‐WTe 3 ‐QD on a screen‐printed carbon electrode (SPCE) by using the 1‐ethyl‐3‐(3‐dimethylaminopropyl)carbodiimide/N‐hydroxysuccinimide (EDC/NHS) coupling chemistry. Thereafter, amine‐terminated 90‐mer ssDNA aptamer was deposited on the modified SPCE and left to cure to form the aptasensor. Using the chronocoulometry signal transduction technique, the aptasensor's calibration with N‐protein gave a linear range value of 1–9 pg.mL −1 and a limit of detection (LOD) value of 0.08 pg.mL −1 . The LOD value of the aptasensor was 8 times lower than the LOD value of 0.71 pg.mL −1 obtained with a commercial N‐protein ELISA kit. When tested in simulated real samples the aptasensor recovery rates of 95–103.33 % were obtained. In the presence of various interferents, the aptasensor displayed good selectivity to N‐protein.

Zitieren

APA

Sanga, N. A., Oranzie, M., Leve, Z., Januarie, K. C., Mokwebo, K. V., Uhuo, O. V., Ross, N., Douman, S. F., Pokpas, K., & Iwuoha, E. I. (2024). Chronocoulometric Quantum Dot Aptasensor for SARS‐CoV‐2 Nucleocapsid Protein Biomarker. ChemElectroChem, 11(14). https://doi.org/10.1002/celc.202400118

Vancouver

Sanga NA, Oranzie M, Leve Z, Januarie KC, Mokwebo KV, Uhuo OV, et al. Chronocoulometric Quantum Dot Aptasensor for SARS‐CoV‐2 Nucleocapsid Protein Biomarker. ChemElectroChem. 2024;11(14). doi:10.1002/celc.202400118

BibTeX
@article{Sanga2024,
  author = {Sanga, Nelia A. and Oranzie, Marlon and Leve, Zandile and Januarie, Kaylin C. and Mokwebo, Kefilwe V. and Uhuo, Onyinyechi V. and Ross, Natasha and Douman, Samantha F. and Pokpas, Keagan and Iwuoha, Emmanuel I.},
  title = {Chronocoulometric Quantum Dot Aptasensor for SARS‐CoV‐2 Nucleocapsid Protein Biomarker},
  journal = {ChemElectroChem},
  year = {2024},
  volume = {11},
  number = {14},
  doi = {10.1002/celc.202400118}
}
Kostenlos starten →