Traumatic Fracture of the Polyethylene Tibial Post in a Posterior‐Stabilized Total Knee Arthroplasty: A Case Report
Clinical Case Reports · 2026-05 · 14 (5)
DOI: 10.1002/ccr3.72705 ↗Kurz gefasst
Fallbericht in der Zeitschrift Clinical Case Reports, online erschienen am 13.05.2026. Verfasst von Zhencan Han und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics Peking University Third Hospital Beijing China. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Natural Science Foundation of Beijing Municipality.
Abstract (Originalsprache)
Posterior‐stabilized total knee arthroplasty (TKA) uses a cam–post mechanism to provide anteroposterior stability, but polyethylene tibial post failure can occur as a rare yet serious complication. We report a case of early TKA failure caused by traumatic tibial post fracture. A patient who underwent primary posterior‐stabilized total knee arthroplasty (TKA) in March 2023 sustained a fall 6 months postoperatively and experienced progressive knee pain and functional deterioration. Clinical and radiographic assessments demonstrated fracture of the polyethylene tibial post, resulting in knee instability and recurvatum. Revision TKA using a rotating‐hinge prosthesis was performed in February 2025. Recurvatum was corrected, and knee stability and function improved. This case underlines that tibial post fracture is an uncommon but serious failure mode after posterior‐stabilized TKA. For patients with severe knee deformity and ligamentous insufficiency, a rotating hinge prosthesis may be a viable option for restoring stability and function.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics Peking University Third Hospital Beijing China.
ORCID-Profile: Hua Tian
Förderung
- Natural Science Foundation of Beijing Municipality
Zitieren
APA
Han, Z., Wang, X., Dong, Z., Li, K., Li, Z., & Tian, H. (2026). Traumatic Fracture of the Polyethylene Tibial Post in a Posterior‐Stabilized Total Knee Arthroplasty: A Case Report. Clinical Case Reports, 14(5). https://doi.org/10.1002/ccr3.72705
Vancouver
Han Z, Wang X, Dong Z, Li K, Li Z, Tian H. Traumatic Fracture of the Polyethylene Tibial Post in a Posterior‐Stabilized Total Knee Arthroplasty: A Case Report. Clinical Case Reports. 2026;14(5). doi:10.1002/ccr3.72705
BibTeX
@article{Han2026,
author = {Han, Zhencan and Wang, Xinguang and Dong, Ziyang and Li, Kangpeng and Li, Zijian and Tian, Hua},
title = {Traumatic Fracture of the Polyethylene Tibial Post in a Posterior‐Stabilized Total Knee Arthroplasty: A Case Report},
journal = {Clinical Case Reports},
year = {2026},
volume = {14},
number = {5},
doi = {10.1002/ccr3.72705}
}
EUVIMED