Hand Microcirculatory Perfusion During Simulated Simultaneous Proximal or Distal Radial and Ulnar Artery Occlusion: A Laser Doppler Study
Catheterization and Cardiovascular Interventions · 09.11.2026
DOI: 10.1002/ccd.70996 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 09.11.2026. Verfasst von Alberto Polimeni und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, Rende, Cosenza, Italy. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
Background
The distal radial artery access has been proposed as an alternative route to overcome some limitations and to reduce complications of conventional radial acces.
Aims
This study aimed to compare hand microcirculatory perfusion during two experimentally induced combined‐compression conditions: combined proximal radial and ulnar artery compression and combined distal radial and ulnar artery compression.
Methods
A prospective, nonrandomized, fixed‐sequence, within‐participant physiological study was conducted on 50 healthy volunteers. Laser Doppler perfusion imaging with PeriScan PIM III device (Perimed AB, Järfälla, Sweden) was employed to quantify palmar microvascular flux during three prespecified sequential conditions: baseline assessment, combined proximal radial and ulnar artery compression, and combined distal radial and ulnar artery compression. Ulnar‐flow cessation was confirmed by Doppler ultrasound before each compressed acquisition. The primary endpoint was the within‐subject difference in palmar perfusion, expressed in terms of perfusion units (PU) in the different experimental conditions. Exploratory subgroup analyses by sex and weight status (normal weight vs. overweight/obese) were performed.
Results
Mean palmar cutaneous microvascular flux was 58.18 ± 23.18 PU at baseline, 5.91 ± 4.48 PU during proximal combined compression, and 28.46 ± 12.69 PU during distal combined compression. At the individual‐participant level, residual flux corresponded to 10.9 ± 8.5% and 50.4 ± 15.8% of baseline during proximal and distal combined compression, respectively. In the primary paired comparison, residual palmar cutaneous microvascular flux was significantly higher during distal than during proximal combined‐compression condition (mean paired difference, 22.56 PU; Bonferroni‐adjusted 95% CI, 18.58–26.53 PU; adjusted p < 0.001). Exploratory condition‐by‐sex ( p = 0.265) and condition‐by‐weight‐status ( p = 0.642) interactions were not statistically significant.
Conclusions
This is the first study to directly compare palmar perfusion during combined proximal versus distal radial and ulnar artery compression using laser Doppler perfusion imaging. The less impaired perfusion during simulated distal radial and ulnar artery occlusion supports a physiological hypothesis regarding the influence of radial compression level on residual cutaneous microvascular flux, particularly when ulnar flow is compromised. However, confirmation in randomized, counterbalanced studies and in patients undergoing coronary procedures is required.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, Rende, Cosenza, Italy.
- Division of Interventional Cardiology, Annunziata Hospital, Cosenza, Italy.
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy.
- Division of Cardiology, Annunziata Hospital, Cosenza, Italy.
- Cardiology Division, Civil Hospital, Ivrea, Torino, Italy.
- Division of Cardiology, Department of Medical and Surgical Sciences, Magna Graecia University, Catanzaro, Italy.
ORCID-Profile: Alberto Polimeni, Domenico Simone Castiello, Giuseppe Panuccio, Francesco Passafaro, Antonio Curcio
Zitieren
APA
Polimeni, A., Castiello, D. S., Basile, N., Sorrentino, S., Panuccio, G., Passafaro, F., Volpe, L., Migliarino, S., Curcio, A., & Indolfi, C. (2026). Hand Microcirculatory Perfusion During Simulated Simultaneous Proximal or Distal Radial and Ulnar Artery Occlusion: A Laser Doppler Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70996
Vancouver
Polimeni A, Castiello DS, Basile N, Sorrentino S, Panuccio G, Passafaro F, et al. Hand Microcirculatory Perfusion During Simulated Simultaneous Proximal or Distal Radial and Ulnar Artery Occlusion: A Laser Doppler Study. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70996
BibTeX
@article{Polimeni2026,
author = {Polimeni, Alberto and Castiello, Domenico Simone and Basile, Nicola and Sorrentino, Sabato and Panuccio, Giuseppe and Passafaro, Francesco and Volpe, Lorenzo and Migliarino, Serena and Curcio, Antonio and Indolfi, Ciro},
title = {Hand Microcirculatory Perfusion During Simulated Simultaneous Proximal or Distal Radial and Ulnar Artery Occlusion: A Laser Doppler Study},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70996}
}
EUVIMED