Covered‐Stent Migration During Same‐Session Aortic Isthmus Repair and Bicuspid Aortic Valve TAVR
Catheterization and Cardiovascular Interventions · 02.11.2026
DOI: 10.1002/ccd.70962 ↗Kurz gefasst
Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 02.11.2026. Verfasst von Georgios E Papadopoulos und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, Interbalkan Medical Center, Thessaloniki, Greece. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
Fixed obstruction at the aortic isthmus may preclude transfemoral transcatheter aortic valve replacement (TAVR). Covered‐stent implantation can restore large‐bore access, but immediate passage of balloons and delivery systems through a newly implanted stent may expose it to longitudinal traction. Secondary stent migration during withdrawal of a valvuloplasty balloon and its intraluminal balloon‐assisted rescue have not been well characterized. An 87‐year‐old man with New York Heart Association class III symptoms had severe bicuspid aortic stenosis (peak velocity, 4.4 m/s; mean gradient, 48 mmHg; valve area, 0.65 cm2; left ventricular ejection fraction, 55%) and a focal juxtaductal aortic‐isthmus stenosis with a peak‐to‐peak gradient of 32 mmHg. Because of high surgical risk and unfavorable alternative access, same‐session covered‐stent treatment followed by transfemoral TAVR was selected. A 12 × 29‐mm Advanta V12 covered stent was deployed and flared using an 18‐mm noncompliant balloon. After aortic‐valve predilation with a 23‐mm noncompliant balloon, the stent migrated distally during balloon withdrawal. Guidewire access was preserved, and the stent remained coaxial. The balloon was recentered within the migrated stent and partially reinflated, allowing the balloon and stent to be advanced proximally as a single unit. After restoration and re‐expansion of the stent, a 23‐mm Myval valve was implanted successfully. Final transvalvular and isthmic gradients were 8 and 5 mmHg, respectively, with trivial paravalvular regurgitation and no aortic injury. The patient was discharged on day 3 and remained in NYHA class I at 6 months. Withdrawal of a large valvuloplasty balloon may cause secondary migration of a newly implanted aortic‐isthmus stent. When guidewire access, coaxial alignment, and structural integrity are preserved, controlled intraluminal balloon‐assisted repositioning may provide an effective bailout while maintaining transfemoral access.
Autor:innen und Institutionen
- Cardiology Department, Interbalkan Medical Center, Thessaloniki, Greece.
ORCID-Profile: Georgios E Papadopoulos, Ilias Ninios, Vlasis Ninios
Zitieren
APA
Papadopoulos, G. E., Ninios, I., & Ninios, V. (2026). Covered‐Stent Migration During Same‐Session Aortic Isthmus Repair and Bicuspid Aortic Valve TAVR. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70962
Vancouver
Papadopoulos GE, Ninios I, Ninios V. Covered‐Stent Migration During Same‐Session Aortic Isthmus Repair and Bicuspid Aortic Valve TAVR. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70962
BibTeX
@article{Papadopoulos2026,
author = {Papadopoulos, Georgios E and Ninios, Ilias and Ninios, Vlasis},
title = {Covered‐Stent Migration During Same‐Session Aortic Isthmus Repair and Bicuspid Aortic Valve TAVR},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70962}
}
EUVIMED