Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 22.09.2026. Verfasst von İskan Zengin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Kayseri City Hospital, Kayseri, Turkey. Hauptthemen laut MEDLINE: Coronary Angiography, Ultrasonography, Interventional, Coronary Artery Disease, Coronary Vessels. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
Background
Intermediate left main coronary artery (LMCA) disease poses a significant diagnostic challenge. Intravascular ultrasound (IVUS) is the guideline‐recommended reference standard for anatomical assessment, whereas quantitative flow ratio (QFR) provides a wire‐free physiological estimate. Conventional coronary angiography (CCA) remains the most widely available assessment modality. However, a systematic three‐way comparison of these modalities in LMCA disease is lacking.
Aims
To compare the diagnostic performance, agreement, and correlations of CCA and QFR with IVUS for the assessment of intermediate LMCA disease.
Methods
This prospective single‐center study enrolled 135 patients with LMCA lesions who underwent CCA, IVUS, and offline QFR (QAngio XA 3D) between January 2024 and June 2025. IVUS‐derived minimum lumen area (MLA) < 6 mm 2 was defined as anatomically significant disease and served as the reference standard. QFR < 0.80 defined functional significance, while CCA diameter stenosis (DS) ≥ 50% defined angiographic significance. Diagnostic performance, inter‐modality agreement, correlation, and Bland–Altman agreement were assessed.
Results
The mean age was 63.4 ± 9.7 years, and 88.1% of patients were male. IVUS identified significant disease in 92 patients (68.1%), compared with 68 (50.4%) by CCA and 50 (37.0%) by QFR. Against the IVUS reference standard, CCA demonstrated 67.4% sensitivity and 86.0% specificity (κ = 0.465; AUC = 0.824; optimal threshold DS ≥ 47%), whereas QFR demonstrated 54.3% sensitivity and 100% specificity (κ = 0.426; AUC = 0.848; Youden‐optimal cutoff QFR ≤ 0.49). CCA correlated moderately with IVUS‐derived MLA (r = −0.384; p < 0.001) and QFR (r = −0.512; p < 0.001). Both CCA and QFR systematically underestimated vessel dimensions relative to IVUS (Bland–Altman bias: CCA − 2.50 mm 2 ; QFR − 2.21 mm 2 ). On multivariable analysis, CCA DS ≥ 50% (OR 2.87; p = 0.011), decreasing QFR value per 0.1‐unit (OR 0.61; p = 0.019), and distal bifurcation location (OR 2.38; p = 0.045) independently predicted IVUS‐defined significant disease.
Conclusion
QFR demonstrated perfect specificity and may serve as a rule‐in tool, whereas CCA provided greater sensitivity for initial triage. Neither modality can replace IVUS for anatomical characterization and procedural planning. A multimodality approach may therefore be appropriate for the assessment of intermediate LMCA stenosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Kayseri City Hospital, Kayseri, Turkey.
- Department of Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery, Educatıon Research Hospıtal, İstanbul, Turkey.
- Department of Cardiology, Erciyes University Faculty of Medicine, Kayseri, Turkey.
- Memorial Hospital Kayseri, Kayseri, Turkey.
- Department of Cardiology, Ağrı State Hospital, Ağrı, Turkey.
- Department of Cardiology, Edirne Uzunköprü State Hospital, Edirne, Turkey.
ORCID-Profile: İskan Zengin, Fuat Polat, Deniz Elçik, Erlan Abibulaev, Ramazan Ozan, Rıdvan Yurt, Nihat Kalay, Saban Keleşoğlu, Cuma Süleymanoğlu, İsmail Düzgün, Namık Kemal Eryol
Zitieren
APA
Zengin, İ., Polat, F., Elçik, D., Abibulaev, E., Ozan, R., Yurt, R., Kalay, N., Keleşoğlu, S., Süleymanoğlu, C., Düzgün, İ., & Eryol, N. K. (2026). Head‐to‐Head Comparison of Quantitative Flow Ratio, Intravascular Ultrasound, and Coronary Angiography in Left Main Coronary Artery Disease. Catheterization and Cardiovascular Interventions, 108(6), 2233-2242. https://doi.org/10.1002/ccd.70918
Vancouver
Zengin İ, Polat F, Elçik D, Abibulaev E, Ozan R, Yurt R, et al. Head‐to‐Head Comparison of Quantitative Flow Ratio, Intravascular Ultrasound, and Coronary Angiography in Left Main Coronary Artery Disease. Catheterization and Cardiovascular Interventions. 2026;108(6):2233-2242. doi:10.1002/ccd.70918
BibTeX
@article{Zengin2026,
author = {Zengin, İskan and Polat, Fuat and Elçik, Deniz and Abibulaev, Erlan and Ozan, Ramazan and Yurt, Rıdvan and Kalay, Nihat and Keleşoğlu, Saban and Süleymanoğlu, Cuma and Düzgün, İsmail and Eryol, Namık Kemal},
title = {Head‐to‐Head Comparison of Quantitative Flow Ratio, Intravascular Ultrasound, and Coronary Angiography in Left Main Coronary Artery Disease},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {108},
number = {6},
pages = {2233--2242},
doi = {10.1002/ccd.70918}
}
EUVIMED