Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve
Catheterization and Cardiovascular Interventions · 2026-11 · 108 (6) · 2130-2140
DOI: 10.1002/ccd.70879 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 17.09.2026. Verfasst von Matteo Casenghi und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Sant'Andrea Hospital, Rome, Italy. Hauptthemen laut MEDLINE: Hemodynamics, Heart Valve Prosthesis, Aortic Valve, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
Background
Patients with small aortic annuli undergoing transcatheter aortic valve implantation (TAVI) are at risk of higher residual transvalvular gradients. Evidence on the performance of new‐generation intra‐annular self‐expanding valves in this anatomical setting remains limited.
Aims
To evaluate the impact of annular size on procedural, hemodynamic, and mid‐term clinical outcomes after TAVI with the Navitor valve.
Methods
Patients were stratified by annular area measured by multi‐slice computed tomography, defining a small annulus as ≤ 430 mm 2 . Primary endpoints at 12 months were: (i) a clinical composite of all‐cause death, disabling stroke, or heart failure rehospitalization, and (ii) a composite endpoint of bioprosthetic valve dysfunction. Secondary endpoints included VARC‐3–defined procedural and early outcomes and valve hemodynamic performance.
Results
The study population comprised 218 patients, of whom 91 (41.7%) had a small annulus. VARC‐3 technical success was high and comparable between small and non‐small annuli (96.7% vs. 96.1%). Patients with small annuli had higher early post‐procedural mean transvalvular gradients (7.7 ± 3.8 vs. 6.6 ± 3.0 mmHg; p = 0.029) and smaller effective orifice areas index (1.1 ± 0.3 vs. 1.3 ± 0.2 cm 2 /m 2 ; p = 0.037), while the incidence of mean gradients ≥ 20 mmHg remained low (1.1% vs. 0.0%; p = 0.432). At 12 months, the clinical composite endpoint occurred in 8.8% of patients with small annuli and 10.2% with non‐small annuli ( p = 0.759). Bioprosthetic valve dysfunction was infrequent and similar between groups (6.6% vs. 6.3%; p = 0.875).
Conclusions
TAVI with the Navitor intra‐annular self‐expanding valve was associated with high procedural success, favorable valve hemodynamics, and comparable mid‐term clinical outcomes irrespective of annular size.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cardiology, Sant'Andrea Hospital, Rome, Italy.
- Department of Clinical and Molecular Medicine, Sapienza University, Rome, Italy.
- Cardiovascular Center Aalst, AZORG, Aalst, Belgium.
ORCID-Profile: Matteo Casenghi, Sara Corradetti, Pasquale Paolisso, Marta Belmonte, Emanuele Gallinoro, Carlo Barsali, Stefano Rigattieri, Marc Vanderheyden
Zitieren
APA
Casenghi, M., Corradetti, S., Paolisso, P., Belmonte, M., Gallinoro, E., Fiori, E., Piras, L., Barzetti, D., Tufo, R., Barsali, C., Rigattieri, S., Rosseel, L., Wyffels, E., Berni, A., Vanderheyden, M., & Barbato, E. (2026). Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve. Catheterization and Cardiovascular Interventions, 108(6), 2130-2140. https://doi.org/10.1002/ccd.70879
Vancouver
Casenghi M, Corradetti S, Paolisso P, Belmonte M, Gallinoro E, Fiori E, et al. Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve. Catheterization and Cardiovascular Interventions. 2026;108(6):2130-2140. doi:10.1002/ccd.70879
BibTeX
@article{Casenghi2026,
author = {Casenghi, Matteo and Corradetti, Sara and Paolisso, Pasquale and Belmonte, Marta and Gallinoro, Emanuele and Fiori, Emiliano and Piras, Linda and Barzetti, Daniele and Tufo, Rita and Barsali, Carlo and Rigattieri, Stefano and Rosseel, Liesbeth and Wyffels, Eric and Berni, Andrea and Vanderheyden, Marc and Barbato, Emanuele},
title = {Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {108},
number = {6},
pages = {2130--2140},
doi = {10.1002/ccd.70879}
}
EUVIMED