Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve

Matteo Casenghi iD, Sara Corradetti iD, Pasquale Paolisso iD, Marta Belmonte iD, Emanuele Gallinoro iD, Emiliano Fiori, Linda Piras, Daniele Barzetti, Rita Tufo, Carlo Barsali iD, Stefano Rigattieri iD, Liesbeth Rosseel und 4 weitere

Catheterization and Cardiovascular Interventions · 2026-11 · 108 (6) · 2130-2140

DOI: 10.1002/ccd.70879 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 17.09.2026. Verfasst von Matteo Casenghi und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Sant'Andrea Hospital, Rome, Italy. Hauptthemen laut MEDLINE: Hemodynamics, Heart Valve Prosthesis, Aortic Valve, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Patients with small aortic annuli undergoing transcatheter aortic valve implantation (TAVI) are at risk of higher residual transvalvular gradients. Evidence on the performance of new‐generation intra‐annular self‐expanding valves in this anatomical setting remains limited.

Aims

To evaluate the impact of annular size on procedural, hemodynamic, and mid‐term clinical outcomes after TAVI with the Navitor valve.

Methods

Patients were stratified by annular area measured by multi‐slice computed tomography, defining a small annulus as ≤ 430 mm 2 . Primary endpoints at 12 months were: (i) a clinical composite of all‐cause death, disabling stroke, or heart failure rehospitalization, and (ii) a composite endpoint of bioprosthetic valve dysfunction. Secondary endpoints included VARC‐3–defined procedural and early outcomes and valve hemodynamic performance.

Results

The study population comprised 218 patients, of whom 91 (41.7%) had a small annulus. VARC‐3 technical success was high and comparable between small and non‐small annuli (96.7% vs. 96.1%). Patients with small annuli had higher early post‐procedural mean transvalvular gradients (7.7 ± 3.8 vs. 6.6 ± 3.0 mmHg; p = 0.029) and smaller effective orifice areas index (1.1 ± 0.3 vs. 1.3 ± 0.2 cm 2 /m 2 ; p = 0.037), while the incidence of mean gradients ≥ 20 mmHg remained low (1.1% vs. 0.0%; p = 0.432). At 12 months, the clinical composite endpoint occurred in 8.8% of patients with small annuli and 10.2% with non‐small annuli ( p = 0.759). Bioprosthetic valve dysfunction was infrequent and similar between groups (6.6% vs. 6.3%; p = 0.875).

Conclusions

TAVI with the Navitor intra‐annular self‐expanding valve was associated with high procedural success, favorable valve hemodynamics, and comparable mid‐term clinical outcomes irrespective of annular size.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemodynamicsHeart Valve ProsthesisAortic ValveTranscatheter Aortic Valve ReplacementAortic Valve StenosisHumansProsthesis DesignTreatment OutcomeAged, 80 and overFemaleMaleTime FactorsRisk FactorsBioprosthesisAgedMultidetector Computed TomographyRecovery of FunctionRetrospective StudiesRisk AssessmentProsthesis Failure

Autor:innen und Institutionen

  • Department of Cardiology, Sant'Andrea Hospital, Rome, Italy.
  • Department of Clinical and Molecular Medicine, Sapienza University, Rome, Italy.
  • Cardiovascular Center Aalst, AZORG, Aalst, Belgium.

ORCID-Profile: Matteo Casenghi, Sara Corradetti, Pasquale Paolisso, Marta Belmonte, Emanuele Gallinoro, Carlo Barsali, Stefano Rigattieri, Marc Vanderheyden

Zitieren

APA

Casenghi, M., Corradetti, S., Paolisso, P., Belmonte, M., Gallinoro, E., Fiori, E., Piras, L., Barzetti, D., Tufo, R., Barsali, C., Rigattieri, S., Rosseel, L., Wyffels, E., Berni, A., Vanderheyden, M., & Barbato, E. (2026). Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve. Catheterization and Cardiovascular Interventions, 108(6), 2130-2140. https://doi.org/10.1002/ccd.70879

Vancouver

Casenghi M, Corradetti S, Paolisso P, Belmonte M, Gallinoro E, Fiori E, et al. Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve. Catheterization and Cardiovascular Interventions. 2026;108(6):2130-2140. doi:10.1002/ccd.70879

BibTeX
@article{Casenghi2026,
  author = {Casenghi, Matteo and Corradetti, Sara and Paolisso, Pasquale and Belmonte, Marta and Gallinoro, Emanuele and Fiori, Emiliano and Piras, Linda and Barzetti, Daniele and Tufo, Rita and Barsali, Carlo and Rigattieri, Stefano and Rosseel, Liesbeth and Wyffels, Eric and Berni, Andrea and Vanderheyden, Marc and Barbato, Emanuele},
  title = {Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {108},
  number = {6},
  pages = {2130--2140},
  doi = {10.1002/ccd.70879}
}
Kostenlos starten →