Long‐Term Cardiovascular Outcomes Following Percutaneous Coronary Intervention of Diffuse Coronary Artery Lesions With Overlapping Homogeneous Versus Heterogeneous Second‐Generation Drug‐Eluting Stents
Catheterization and Cardiovascular Interventions · 31.07.2026
DOI: 10.1002/ccd.70781 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 31.07.2026. Verfasst von Nagendra Boopathy Senguttuvan und 31 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India. Hauptthemen laut MEDLINE: Percutaneous Coronary Intervention, Coronary Artery Disease, Drug-Eluting Stents. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Background and Aims The growing prevalence and severity of diffuse coronary artery disease (dCAD) necessitate the utilization of appropriate stenting techniques to ensure complete target lesion coverage. In clinical settings where overlapping stents are the norm, there is inconclusive evidence to determine whether using stents of the same identity produces better outcomes compared to stents that differ in material characteristics. Methods and Results We conducted a retrospective observational cohort study at two high‐volume, tertiary cardiac care centers in India to determine the safety and efficacy of homogeneous overlapping stents (HOSTs) and heterogeneous overlapping stents (HESTs) in patients with dCAD undergoing percutaneous coronary intervention (PCI). Patients were stratified into complex and non‐complex subgroups based on pre‐specified clinical and angiographic criteria. Out of 12,920 interventions that were performed during the study period (January 2016 to December 2023), 972 procedures utilized overlapping stent strategies, of which 935 cases met the inclusion and exclusion criteria. HOSTs were used in 795 patients, while HESTs were used in 140 patients. To account for imbalances in the study population, inverse probability of treatment weighting (IPTW) was applied following propensity score adjustment via logistic regression modeling. During a mean follow‐up of 2.5 years, occurrence of major adverse cardiovascular events (MACE) was comparable between HOST and HEST groups in the unadjusted (odds ratio [OR] 0.91, 95% confidence interval [CI]: 0.59−1.42, p = 0.67), as well as adjusted population (OR 1.05, 95% CI: 0.69−1.61, p = 0.81). Similar trends were observed in the complexity‐stratified populations, with no evidence of benefit or harm associated with either stenting strategy. Conclusion Overlapping heterogeneous stents yield similar clinical outcomes as homogeneous stents, regardless of procedural complexity, suggesting that operators may use a “mix‐and‐match” strategy when ideal stent pairings are not feasible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India.
- Department of Cardiology, ASTER Malabar Institute of Medical Sciences (MIMS), Calicut, Kerala, India.
- ICMR-National Institute of Epidemiology, Chennai, Tamil Nadu, India.
- Department of Clinical Research, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India.
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India.
- Department of Cardiovascular Technology, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India.
ORCID-Profile: Nagendra Boopathy Senguttuvan, Salman Salahuddin, Swetharajan Gunasekar, Dharaneswari Hari Narayanan, Vinod Kumar Balakrishnan
Zitieren
APA
Senguttuvan, N. B., Salahuddin, S., Abdulkader, R. S., Gunasekar, S., Narayanan, D. H., Kumar, P. S., Mohanan, S., Mahesh, K. V., Ganesh, M., Prabhakaran, K., Thota, M. K., Karthikeyan, G. G., Ramesh, A., Ramachandran, P., Begam, B., Lakshmanan, G., Ravi, T., Chidambaram, Y., Kasi, M., …, & Thanikachalam, S. (2026). Long‐Term Cardiovascular Outcomes Following Percutaneous Coronary Intervention of Diffuse Coronary Artery Lesions With Overlapping Homogeneous Versus Heterogeneous Second‐Generation Drug‐Eluting Stents. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70781
Vancouver
Senguttuvan NB, Salahuddin S, Abdulkader RS, Gunasekar S, Narayanan DH, Kumar PS, et al. Long‐Term Cardiovascular Outcomes Following Percutaneous Coronary Intervention of Diffuse Coronary Artery Lesions With Overlapping Homogeneous Versus Heterogeneous Second‐Generation Drug‐Eluting Stents. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70781
BibTeX
@article{Senguttuvan2026,
author = {Senguttuvan, Nagendra Boopathy and Salahuddin, Salman and Abdulkader, Rizwan Suliankatchi and Gunasekar, Swetharajan and Narayanan, Dharaneswari Hari and Kumar, Pavitraa Saravana and Mohanan, Sandeep and Mahesh, Keerthana Vaishnavi and Ganesh, Monisha and Prabhakaran, Kavitha and Thota, Mohan Kumar and Karthikeyan, Gautam Ganesan and Ramesh, Aravind and Ramachandran, Pavithra and Begam, Benasir and Lakshmanan, Gokulalakshmi and Ravi, Thrisha and Chidambaram, Yogapriya and Kasi, Madhesh and Anandaram, Asuwin and Prashanth, Akshay and Arul, Judah Nijas and Krishnamurthy, Preetam and Balasubramaniyan, Jayanty Venkata and Balakrishnan, Vinod Kumar and Shanmugasundaram, Sadhanandham and Ramesh, Sankaran and Panchanatham, Manokar and Iyer, Meena and Murthy, Jayanty Satyanarayana and Muralidharan, Thoddi Ramamurthy and Thanikachalam, Sadagopan},
title = {Long‐Term Cardiovascular Outcomes Following Percutaneous Coronary Intervention of Diffuse Coronary Artery Lesions With Overlapping Homogeneous Versus Heterogeneous Second‐Generation Drug‐Eluting Stents},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70781}
}
EUVIMED