EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

VERMONT μQFR: Diagnostic Accuracy of Murray Law‐Based 2D‐μQFR Compared to 3D‐μQFR and vFFR

Daniel Akrawi iD, Krishna Kadappu, James Xu, Tamer Yousef Naguib Badie, Oliver Gibbs, Hashim Kachwalla, Phong T D Nguyen, Rahul Kurup, Upul Premawardhana, Justyn Huang, Hao Tran, Kavie Soosapilla und 5 weitere

Catheterization and Cardiovascular Interventions · 27.07.2026

DOI: 10.1002/ccd.70768 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 27.07.2026. Verfasst von Daniel Akrawi und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Campbelltown Hospital, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Imaging, Three-Dimensional, Coronary Angiography, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Murray law‐based quantitative flow ratio (μQFR) is an angiography‐derived physiological index that utilizes a single angiographic projection with artificial intelligence‐guided vessel segmentation.

Aims

To evaluate the diagnostic accuracy and time efficacy of 2D‐μQFR against wire‐based fractional flow reserve (FFR ≤ 0.80), compare its performance with 3D‐μQFR and vessel‐FFR (vFFR), and assess feasibility in lesions excluded from vFFR analysis.

Methods

This sub‐study of the prospective VERMONT trial analyzed 2D‐ and 3D‐μQFR retrospectively using prospectively acquired angiograms, with wire‐based FFR as the reference standard.

Results

Among 209 patients with 225 intermediate lesions, 205 lesions were analyzed. 2D‐μQFR demonstrated excellent diagnostic accuracy for FFR ≤ 0.80 (AUC 0.95; 95% CI 0.93–0.98), with 93% sensitivity, 92% specificity, 88% positive predictive value (PPV), and 95% negative predictive value (NPV). Inter‐observer agreement was excellent ( r = 0.94, p < 0.001), and 2D‐μQFR analysis was 15.1 min faster than wire‐based FFR (1.8 ± 0.7 vs. 16.9 ± 5.4 min, p < 0.001). Diagnostic performance was comparable to that of 3D‐μQFR, which achieved an AUC of 0.94 (95% CI 0.91–0.97), with 89% sensitivity, 90% specificity, 86% PPV, and 93% NPV. It was more specific than vFFR, which achieved an AUC of 0.92 (95% CI 0.89–0.96), with 90% sensitivity, 79% specificity, 74% PPV, and 93% NPV. Single‐projection analysis was feasible in 85% of lesions excluded from vFFR due to image quality limitations.

Conclusion

Single‐projection 2D‐μQFR provides accurate, rapid, and reproducible physiological assessment comparable to 3D‐μQFR with superior specificity to vFFR. These findings support 2D‐μQFR as a practical, wire‐free alternative to invasive FFR in routine clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialImaging, Three-DimensionalCoronary AngiographyRadiographic Image Interpretation, Computer-AssistedCoronary VesselsCardiac CatheterizationCoronary Artery DiseaseHumansPredictive Value of TestsFemaleReproducibility of ResultsProspective StudiesFeasibility StudiesMaleRetrospective StudiesAgedMiddle AgedTime Factors

Stichwörter der Autor:innen

FFRMurray law‐based quantitative flow ratioangiogram based fractional flow reservefractional flow reservevFFRvessel fractional flow reserveμQFR

Autor:innen und Institutionen

  • Department of Cardiology, Campbelltown Hospital, Sydney, New South Wales, Australia.
  • Department of Cardiology, Liverpool Hospital, Sydney, New South Wales, Australia.
  • School of Medicine, Western Sydney University, Campbelltown, New South Wales, Australia.
  • Faculty of Medicine, University of New South Wales, Liverpool, New South Wales, Australia.
  • Faculty of Medicine and Health, University of Sydney, Westmead, New South Wales, Australia.
  • School of Computer, Data & Mathematical Sciences, Western Sydney University, Campbelltown, New South Wales, Australia.

ORCID-Profile: Daniel Akrawi

Zitieren

APA

Akrawi, D., Kadappu, K., Xu, J., Badie, T. Y. N., Gibbs, O., Kachwalla, H., Nguyen, P. T. D., Kurup, R., Premawardhana, U., Huang, J., Tran, H., Soosapilla, K., Basilakis, J., O'loughlin, A., Hennessy, A., Femia, G., & Lo, S. (2026). VERMONT μQFR: Diagnostic Accuracy of Murray Law‐Based 2D‐μQFR Compared to 3D‐μQFR and vFFR. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70768

Vancouver

Akrawi D, Kadappu K, Xu J, Badie TYN, Gibbs O, Kachwalla H, et al. VERMONT μQFR: Diagnostic Accuracy of Murray Law‐Based 2D‐μQFR Compared to 3D‐μQFR and vFFR. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70768

BibTeX
@article{Akrawi2026,
  author = {Akrawi, Daniel and Kadappu, Krishna and Xu, James and Badie, Tamer Yousef Naguib and Gibbs, Oliver and Kachwalla, Hashim and Nguyen, Phong T D and Kurup, Rahul and Premawardhana, Upul and Huang, Justyn and Tran, Hao and Soosapilla, Kavie and Basilakis, Jim and O'loughlin, Aiden and Hennessy, Annemarie and Femia, Giuseppe and Lo, Sidney},
  title = {VERMONT μQFR: Diagnostic Accuracy of Murray Law‐Based 2D‐μQFR Compared to 3D‐μQFR and vFFR},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70768}
}
Kostenlos starten →