Impact of Strut Thickness for Patients Treated With Percutaneous Revascularization for Coronary Bifurcations: Insights From the BIFURCAT‐ULTRA Registry
Catheterization and Cardiovascular Interventions · 2026-08 · 108 (2) · 554-563
DOI: 10.1002/ccd.70669 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 02.06.2026. Verfasst von Matteo Michelone und 27 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular and Thoracic Department, Division of Cardiology, Città della Salute e della Scienza Hospital, Turin, Italy. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Coronary Artery Disease, Percutaneous Coronary Intervention. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Whether strut thickness influences clinical outcomes after percutaneous coronary intervention (PCI) for bifurcation lesions remains debated.
Aims
To compare the safety and efficacy of ultrathin (< 70 µm) drug‐eluting stents (DES) with thicker DES in coronary bifurcations.
Methods
We pooled patient‐level data from the ULTRA and BIFURCAT registries. Stents were classified as thick (≥ 100 µm), thin (70–100 µm), or ultrathin (< 70 µm). The primary endpoint was target‐lesion revascularization (TLR). Inverse probability of treatment weighting (IPTW) balanced baseline characteristics overall and within procedural subgroups (provisional vs. planned two‐stent strategy).
Results
Among 6753 patients (median follow‐up 800 days, IQR 400–900), 514 (8%) received thick, 5139 (76%) thin, and 1100 (16%) ultrathin stents. Crude TLR rates were 3.3%, 2.8%, and 1.1%, respectively ( p = 0.001). After IPTW adjustment, ultrathin DES significantly reduced TLR compared with thick DES (HR 0.38, 95% CI = 0.16–0.89, p = 0.03) and with thin DES (HR 0.41, 95% CI 0.21–0.81, p = 0.01). In provisional‐stenting cases, TLR risk did not differ across groups (HR: 0.53 vs. thick, p = 0.27; HR: 0.49 vs. thin, p = 0.07). Conversely, in planned two‐stent procedures ultrathin DES resulted associated with TLR reduction versus thick DES (HR: 0.21, 95% CI 0.04–0.93, p = 0.04), with a nonsignificant trend for thin DES (HR: 0.31, p = 0.07).
Conclusions
In contemporary bifurcation PCI, ultrathin DES are associated with a clinically and statistically significant reduction in repeat revascularization compared with thicker‐strut platforms, a benefit driven predominantly by lesions treated with an upfront two‐stent approach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiovascular and Thoracic Department, Division of Cardiology, Città della Salute e della Scienza Hospital, Turin, Italy.
- Department of Internal Medicine, Division of Cardiology, Keimyung University Dongsan Hospital, Daegu, Republic of Korea.
- Department of Internal Medicine, Cardiovascular Center, Seoul National University Hospital, Seoul, Republic of Korea.
- Division of Cardiology, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy.
- Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
- Department of Clinical Internal, Anesthesiology and Cardiovascular Sciences, Sapienza University of Rome, Rome, Italy.
ORCID-Profile: Matteo Michelone, Fabrizio D'Ascenzo, Leonardo De Luca, Gianluca Di Pietro, Sebastiano Gili, Hyun Kuk Kim, Antonio Greco, Chang-Wook Nam
Zitieren
APA
Michelone, M., D'Ascenzo, F., Cho, Y. K., Kang, J., De Luca, L., Cimino, A. R., Choi, K. H., Di Pietro, G., Bertello, E., Mattesini, A., Wanha, W., Lee, S. Y., Gili, S., Kim, H. K., Capoccia, S., Greco, A., Iannaccone, M., Lee, H. J., Cortese, B., …, & De Filippo, O. (2026). Impact of Strut Thickness for Patients Treated With Percutaneous Revascularization for Coronary Bifurcations: Insights From the BIFURCAT‐ULTRA Registry. Catheterization and Cardiovascular Interventions, 108(2), 554-563. https://doi.org/10.1002/ccd.70669
Vancouver
Michelone M, D'Ascenzo F, Cho YK, Kang J, De Luca L, Cimino AR, et al. Impact of Strut Thickness for Patients Treated With Percutaneous Revascularization for Coronary Bifurcations: Insights From the BIFURCAT‐ULTRA Registry. Catheterization and Cardiovascular Interventions. 2026;108(2):554-563. doi:10.1002/ccd.70669
BibTeX
@article{Michelone2026,
author = {Michelone, Matteo and D'Ascenzo, Fabrizio and Cho, Yun-Kyeong and Kang, Jeehoon and De Luca, Leonardo and Cimino, Andrea Rino and Choi, Ki Hong and Di Pietro, Gianluca and Bertello, Eleonora and Mattesini, Alessio and Wanha, Wojciech and Lee, Sang Yeub and Gili, Sebastiano and Kim, Hyun Kuk and Capoccia, Sergio and Greco, Antonio and Iannaccone, Mario and Lee, Hyun-Jong and Cortese, Bernardo and Song, Young Bin and Capodanno, Davide and Gwon, Hyeon-Cheol and Bruno, Francesco and Tuttolomondo, Domenico and Koo, Bon-Kwon and De Ferrari, Gaetano Maria and Nam, Chang-Wook and De Filippo, Ovidio},
title = {Impact of Strut Thickness for Patients Treated With Percutaneous Revascularization for Coronary Bifurcations: Insights From the BIFURCAT‐ULTRA Registry},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {108},
number = {2},
pages = {554--563},
doi = {10.1002/ccd.70669}
}
EUVIMED