Impact of Plaque Eccentricity on the Diagnostic Performance of Murray‐Law Based Quantitative Flow Ratio Computed From a Single Angiographic View
Catheterization and Cardiovascular Interventions · 2026-07 · 108 (1) · 163-173
DOI: 10.1002/ccd.70642 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 22.04.2026. Verfasst von Daixin Ding und 11 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Plaque, Atherosclerotic, Fractional Flow Reserve, Myocardial, Coronary Angiography, Computed Tomography Angiography. Die Arbeit nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shanghai Magnolia Talent Program Pujiang Project.
Abstract (Originalsprache)
Background
Murray‐law based quantitative flow ratio (μFR) enables rapid fractional flow reserve (FFR) computation from invasive coronary angiography (ICA) using a single projection, but the influence of plaque eccentricity on its diagnostic accuracy remains unclear.
Aims
To investigate whether eccentric plaque impacts the diagnostic accuracy of single‐view μFR.
Methods
We performed a blinded analysis of the prospective CAREER trial database, enrolling patients with 30%−90% diameter stenosis on coronary computed tomography angiography (CCTA) who underwent μFR and FFR assessments within 30 days. ICA were acquired using standardized, protocol‐specified projections. CCTA images were analyzed using dedicated software and co‐registered with ICA. For each μFR‐identified lesion, plaque eccentricity index (PEI) and lumen asymmetry index (LAI) were computed across all cross‐sections and averaged to yield PEI and LAI per‐vessel. Vessels were classified as having eccentric/concentric plaques using median PEI, and subclassified as having asymmetric/symmetric lumens using median LAI.
Results
Among 231 vessels (201 patients), median μFR and FFR were 0.84 and 0.83, respectively. PEI and LAI moderately correlated ( ρ = 0.46, p < 0.001). Limits of agreement between μFR and FFR were wider in eccentric versus concentric plaques (standard deviation 0.08 vs. 0.06; p = 0.003), mainly driven by presence of asymmetric lumens (standard deviation 0.09 vs. 0.06 in symmetric lumens; p = 0.029). μFR had comparable AUC for predicting FFR ≤ 0.80 between concentric plaques and eccentric plaques with symmetric lumens (0.94 vs. 0.95; p = 0.909).
Conclusions
The diagnostic accuracy of single‐view μFR, derived from standardized angiographic projections, was moderately affected by eccentric plaques, with the effect primarily attributable to asymmetric lumens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Department of Cardiology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
- Department of Active Medical Device Inspection, Shanghai Medical Device and Cosmetics Evaluation and Verification Center, Shanghai, China.
- Department of Cardiology, Huadong Hospital Affiliated to Fudan University, Shanghai, China.
- Sanya People's Hospital and West China (Sanya) Hospital, Sichuan University, Sanya, China.
- Department of Radiology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
ORCID-Profile: Daixin Ding, Xinkai Qu, Shengxian Tu
Förderung
- National Natural Science Foundation of China
- Shanghai Magnolia Talent Program Pujiang Project
Zitieren
APA
Ding, D., Wang, X., Li, G., Weng, T., Pan, M., Yang, X., He, R., Guan, S., Qu, X., Li, M., Wijns, W., & Tu, S. (2026). Impact of Plaque Eccentricity on the Diagnostic Performance of Murray‐Law Based Quantitative Flow Ratio Computed From a Single Angiographic View. Catheterization and Cardiovascular Interventions, 108(1), 163-173. https://doi.org/10.1002/ccd.70642
Vancouver
Ding D, Wang X, Li G, Weng T, Pan M, Yang X, et al. Impact of Plaque Eccentricity on the Diagnostic Performance of Murray‐Law Based Quantitative Flow Ratio Computed From a Single Angiographic View. Catheterization and Cardiovascular Interventions. 2026;108(1):163-173. doi:10.1002/ccd.70642
BibTeX
@article{Ding2026,
author = {Ding, Daixin and Wang, Xiaoling and Li, Guanyu and Weng, Tingwen and Pan, Min and Yang, Xinyi and He, Ruilin and Guan, Shaofeng and Qu, Xinkai and Li, Ming and Wijns, William and Tu, Shengxian},
title = {Impact of Plaque Eccentricity on the Diagnostic Performance of Murray‐Law Based Quantitative Flow Ratio Computed From a Single Angiographic View},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {108},
number = {1},
pages = {163--173},
doi = {10.1002/ccd.70642}
}
EUVIMED