Endothelial Activation and Stress Index (EASIX) as a Predictor of No‐Reflow in Patients Undergoing Saphenous Vein Graft Percutaneous Coronary Intervention
Catheterization and Cardiovascular Interventions · 2026-07 · 108 (1) · 67-75
DOI: 10.1002/ccd.70637 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 21.04.2026. Verfasst von Emirhan Hancıoğlu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Acıbadem District Hospital, Istanbul Medipol University, Istanbul, Kadıkoy, Turkey. Hauptthemen laut MEDLINE: No-Reflow Phenomenon, Percutaneous Coronary Intervention, Saphenous Vein, Endothelium, Vascular. Die Arbeit nennt 42 Literaturangaben.
Abstract (Originalsprache)
Background
No‐reflow phenomenon (NRP) is a significant complication of percutaneous coronary intervention (PCI) in saphenous vein grafts (SVGs). The Endothelial Activation and Stress Index (EASIX), derived from LDH, creatinine, and platelet count, is a marker of endothelial dysfunction and inflammation.
Aims
To assess the association between EASIX and NRP in patients undergoing SVG PCI.
Methods
A total of 343 patients with non‐ST elevation myocardial infarction who underwent SVG PCI between March 2020 and June 2025 were retrospectively enrolled. Patients were categorized according to the development of NRP. Multivariate logistic regression identified independent predictors, and the discriminative performance of EASIX was assessed using receiver operating characteristic (ROC) curves.
Results
NRP occurred in 71 patients (20.7%). Patients with NRP had higher EASIX scores (1.61 ± 1.43 vs. 0.73 ± 0.36, p < 0.001), neutrophil‐to‐lymphocyte ratio (NLR), and systemic immune‐inflammation index (SII). EASIX (OR: 3.151, p = 0.001), NLR, and reduced left ventricular ejection fraction were independent predictors of NRP. ROC analysis indicated that EASIX predicted NRP with an AUC of 0.779 (95% CI: 0.711–0.847, p < 0.001). The optimal EASIX cut‐off was 0.79, with 70% sensitivity and 68% specificity.
Conclusion
EASIX, a simple and easily calculated score, is independently associated with no‐reflow in patients undergoing SVG PCI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, Acıbadem District Hospital, Istanbul Medipol University, Istanbul, Kadıkoy, Turkey.
- Department of Cardiology, Bağcılar Training and Research Hospital, Istanbul, Turkey.
- Department of Cardiology, Bilecik Training and Research Hospital, Bilecik, Turkey.
- Department of Cardiology, Istanbul Bayrampaşa Kolan Hospital, Istanbul, Turkey.
ORCID-Profile: Emirhan Hancıoğlu, Emre Melik Faideci, Erdem Karaçöp
Zitieren
APA
Hancıoğlu, E., Özcan, S., Faideci, E. M., Bekler, Ö., Karaçöp, E., Enhoş, A., & Okuyan, E. (2026). Endothelial Activation and Stress Index (EASIX) as a Predictor of No‐Reflow in Patients Undergoing Saphenous Vein Graft Percutaneous Coronary Intervention. Catheterization and Cardiovascular Interventions, 108(1), 67-75. https://doi.org/10.1002/ccd.70637
Vancouver
Hancıoğlu E, Özcan S, Faideci EM, Bekler Ö, Karaçöp E, Enhoş A, et al. Endothelial Activation and Stress Index (EASIX) as a Predictor of No‐Reflow in Patients Undergoing Saphenous Vein Graft Percutaneous Coronary Intervention. Catheterization and Cardiovascular Interventions. 2026;108(1):67-75. doi:10.1002/ccd.70637
BibTeX
@article{Hancolu2026,
author = {Hancıoğlu, Emirhan and Özcan, Sevgi and Faideci, Emre Melik and Bekler, Özkan and Karaçöp, Erdem and Enhoş, Asım and Okuyan, Ertuğrul},