EUVIMEDEUVIMED entdecken
Multizentrische Studie

Transcatheter Aortic Valve Implantation via Percutaneous Axillary Access—A UK Registry

Noman Ali, Michael S Cunnington, Douglas Muir, Seth Vijayan, Pyotr Telyuk, Adnan M Nadir, Mark Zorman, Rajesh Kharbanda, Daniel J Blackman, Christopher J Malkin, Ciprian Dospinescu, Arul Baradi und 8 weitere

Catheterization and Cardiovascular Interventions · 2026-03 · 107 (4) · 997-1004

DOI: 10.1002/ccd.70435 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 17.12.2025. Verfasst von Noman Ali und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Axillary Artery, Catheterization, Peripheral, Aortic Valve Stenosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Alternative access for transcatheter aortic valve implantation (TAVI) is required for the small subset of patients in whom transfemoral (TF) access is not feasible. The most commonly used alternative access route in the United Kingdom is the subclavian/axillary artery, and historically, most have been performed via surgical cutdown. Transaxillary TAVI can be undertaken via a percutaneous route. However, there exists limited data on the safety and efficacy of this technique.

Aims

This study aims to describe the UK experience of percutaneous axillary (PAx) TAVI.

Methods

This retrospective, multicenter study included every TAVI center in the United Kingdom which had performed > 10 PAx TAVI cases as of November 1, 2023. Each center provided data on all PAx cases carried out up to December 31, 2023. Procedural and clinical endpoints as well as adverse events were assessed according to Valve Academic Research Consortium (VARC)‐3 definitions.

Results

Nine UK TAVI centers contributed data from 210 PAx cases. VARC‐3 technical success was achieved in 92.4%. The incidence of major VARC‐3 vascular access site complications was 7.1%, major or life‐threatening VARC‐3 bleeding occurred in 5.3%, a covered stent was used in 25.2%, and vascular surgical intervention was required in 3.3%. The incidence of in‐hospital stroke and mortality were 7.1% and 3.3%, respectively. No statistically significant differences were observed between PAx carried out under conscious sedation (non‐GA) and GA with respect to clinical outcomes.

Conclusion

PAx TAVI is viable and can be performed under conscious sedation with no detriment in terms of clinical outcomes. However, the elevated risk of stroke is a concern.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAxillary ArteryCatheterization, PeripheralAortic Valve StenosisAortic ValveHumansUnited KingdomRetrospective StudiesRegistriesFemaleTreatment OutcomeAged, 80 and overMaleAgedTime FactorsRisk FactorsPuncturesRisk Assessment

Stichwörter der Autor:innen

percutaneous axillary TAVIstroketransaxillary

Autor:innen und Institutionen

  • Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
  • Department of Cardiology, James Cook University Hospital, Middlesborough, UK.
  • Department of Cardiology, Queen Elizabeth University Hospital, Birmingham, UK.
  • Department of Cardiology, Oxford Universities Hospital, Oxford, UK.
  • Department of Cardiology, Aberdeen Royal Infirmary, Aberdeen, UK.
  • Sussex Cardiac Centre, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK.

ORCID-Profile: Vasileios Panoulas

Zitieren

APA

Ali, N., Cunnington, M. S., Muir, D., Vijayan, S., Telyuk, P., Nadir, A. M., Zorman, M., Kharbanda, R., Blackman, D. J., Malkin, C. J., Dospinescu, C., Baradi, A., Hildick-Smith, D., Hartley, A., Malik, I., Dorman, S., Panoulas, V., Konstantinos, K., Doshi, S., & Williams, P. D. (2026). Transcatheter Aortic Valve Implantation via Percutaneous Axillary Access—A UK Registry. Catheterization and Cardiovascular Interventions, 107(4), 997-1004. https://doi.org/10.1002/ccd.70435

Vancouver

Ali N, Cunnington MS, Muir D, Vijayan S, Telyuk P, Nadir AM, et al. Transcatheter Aortic Valve Implantation via Percutaneous Axillary Access—A UK Registry. Catheterization and Cardiovascular Interventions. 2026;107(4):997-1004. doi:10.1002/ccd.70435

BibTeX
@article{Ali2026,
  author = {Ali, Noman and Cunnington, Michael S and Muir, Douglas and Vijayan, Seth and Telyuk, Pyotr and Nadir, Adnan M and Zorman, Mark and Kharbanda, Rajesh and Blackman, Daniel J and Malkin, Christopher J and Dospinescu, Ciprian and Baradi, Arul and Hildick-Smith, David and Hartley, Adam and Malik, Iqbal and Dorman, Stephen and Panoulas, Vasileios and Konstantinos, Konstantinou and Doshi, Sagar and Williams, Paul D},
  title = {Transcatheter Aortic Valve Implantation via Percutaneous Axillary Access—A UK Registry},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {107},
  number = {4},
  pages = {997--1004},
  doi = {10.1002/ccd.70435}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche