Impact of Prolapse Width on Outcomes of Transcatheter Edge‐to‐Edge Repair in Degenerative Mitral Regurgitation

Manchen Gao, Jianrui Ma iD, Yuxiang Tang, Cheng Wang, Fujian Duan, Shouzheng Wang iD, Guangzhi Zhao, Fengwen Zhang, Aijin Xie, Chuangshi Wang, Xiangbin Pan iD

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70384 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Manchen Gao und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Pek…. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Cardiac Catheterization, Mitral Valve, Heart Valve Prosthesis Implantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: This study was supported by the CAMS Innovation Fund for Medical Sciences (2021-I2M-1-065) and the Yunnan Province Science and Technology Department key resear….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transcatheter edge‐to‐edge repair (TEER) is widely used for high‐risk degenerative mitral regurgitation (DMR), but the range of leaflet lesions that can be managed with one single clip remains unclear. This study aimed to evaluate the range of leaflet lesions treatable with one clip during TEER in DMR patients.

Methods

We retrospectively analyzed intraoperative echocardiograms from 106 DMR patients undergoing TEER. Logistic regression was used to identify anatomical factors affecting satisfactory results after the first clip. Optimal cut‐off values were determined using Receiver‐operator characteristics (ROC) curve analysis and subsequently validated with follow‐up data.

Results

Forty‐three patients achieved satisfactory result after the first clip. Multivariate analysis identified prolapse width ( p < 0.001) and prolapse gap ( p = 0.039) as independent predictors for satisfactory result after the first clip. ROC analysis showed superior predictive value for prolapse width (AUC = 0.877 vs. 0.734). The optimal prolapse width cut‐off value was 14 mm when the Youden index reached maximum value of 0.699 (sensitivity 0.746, specificity 0.953). Patients with width > 14 mm had significantly higher adverse event rates (Log‐rank, Breslow, Tarone‐Ware p = 0.007, 0.007, 0.006). Consistent results were also obtained in the subgroup of patients finished TEER with 1 clip (Log‐rank, Breslow, Tarone‐Ware p = 0.065, 0.030, 0.038).

Conclusions

Prolapse width is a key independent predictor of outcomes after the first clip implantation in TEER procedure. The incidence of postoperative severe adverse events is higher in patients with a prolapse width exceeding 14 mm, regardless of the number of clips implanted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve InsufficiencyCardiac CatheterizationMitral ValveHeart Valve Prosthesis ImplantationMitral Valve ProlapseHumansRetrospective StudiesFemaleMaleTreatment OutcomeAgedRisk FactorsAged, 80 and overMiddle AgedTime FactorsRecovery of FunctionRisk AssessmentSurgical Instruments

Stichwörter der Autor:innen

degenerative mitral regurgitationprolapse widthtranscatheter edge‐to‐edge repair

Autor:innen und Institutionen

  • Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, National Health Commission Key Laboratory o…
  • National Clinical Research Center for Cardiovascular Diseases, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Guangdong Province, Shenzhen, China.
  • Department of Echocardiography Imaging Center, National Center for Cardiovascular Diseases, China & Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.

ORCID-Profile: Jianrui Ma, Shouzheng Wang, Xiangbin Pan

Förderung

  • This study was supported by the CAMS Innovation Fund for Medical Sciences (2021-I2M-1-065) and the Yunnan Province Science and Technology Department key resear…

Zitieren

APA

Gao, M., Ma, J., Tang, Y., Wang, C., Duan, F., Wang, S., Zhao, G., Zhang, F., Xie, A., Wang, C., & Pan, X. (2026). Impact of Prolapse Width on Outcomes of Transcatheter Edge‐to‐Edge Repair in Degenerative Mitral Regurgitation. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70384

Vancouver

Gao M, Ma J, Tang Y, Wang C, Duan F, Wang S, et al. Impact of Prolapse Width on Outcomes of Transcatheter Edge‐to‐Edge Repair in Degenerative Mitral Regurgitation. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70384

BibTeX
@article{Gao2026,
  author = {Gao, Manchen and Ma, Jianrui and Tang, Yuxiang and Wang, Cheng and Duan, Fujian and Wang, Shouzheng and Zhao, Guangzhi and Zhang, Fengwen and Xie, Aijin and Wang, Chuangshi and Pan, Xiangbin},
  title = {Impact of Prolapse Width on Outcomes of Transcatheter Edge‐to‐Edge Repair in Degenerative Mitral Regurgitation},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70384}
}
Kostenlos starten →