EUVIMEDEUVIMED entdecken
Video/Audio

A Simple Approach for 3D IVUS‐Angiographic Co‐Registration for CTOs Using the “Be‐The‐Wire” Cognitive Model

Bayushi Eka Putra iD, Yutaka Tadano iD, Umihiko Kaneko iD, Mugilan Sundarajoo, Ivan Satria Pratama, Takuro Sugie, Shoichi Kuramitsu iD, Daitaro Kanno, Yoshifumi Kashima, Tsutomu Fujita iD

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70371 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Bayushi Eka Putra und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Sapporo Cardiovascular Clinic, Sapporo Heart Center, Sapporo, Japan. Hauptthemen laut MEDLINE: Ultrasonography, Interventional, Coronary Angiography, Percutaneous Coronary Intervention, Imaging, Three-Dimensional. Die Arbeit nennt 3 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Percutaneous coronary intervention (PCI) for chronic total occlusions (CTO) is a technically demanding procedure where successful guidewire navigation is critical. While intravascular ultrasound (IVUS) provides essential anatomical detail, its utility is often limited by the cognitive challenge of correlating the 2D IVUS image with the 3D angiographic view. A failure in this co‐registration can lead to procedural failure. To address this challenge, we detail the “Be‐The‐Wire” cognitive model, a simple, six‐step mnemonic‐based method for achieving intuitive 3D IVUS‐angiographic co‐registration. The technique requires the operator to adopt the perspective of being the IVUS‐carrying wire, with their head positioned on the proximal side of the coronary artery. Key steps include optimizing the angiographic view for gear separation, deducing the C‐arm's viewing angle, mapping this angle to a clock‐face position on the IVUS display, and physically rotating the screen to align it with the vessel's trajectory. The “Be‐The‐Wire” cognitive model provides a simple yet profound method to improve guidewire control by facilitating intuitive co‐registration without requiring complex software. Mastering this technique is a valuable step which may potentially contribute to improving safety and success rates in complex CTO PCI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, InterventionalCoronary AngiographyPercutaneous Coronary InterventionImaging, Three-DimensionalCoronary OcclusionRadiographic Image Interpretation, Computer-AssistedCoronary VesselsHumansPredictive Value of TestsChronic Disease

Stichwörter der Autor:innen

IVUS‐angiographic co‐registrationchronic total occlusion (CTO)cognitive modelguidewire navigationprocedural technique

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Sapporo Cardiovascular Clinic, Sapporo Heart Center, Sapporo, Japan.
  • Department of Cardiology, Berkah General Hospital Pandeglang, Kabupaten Pandeglang, Banten, Indonesia.
  • Department of Cardiovascular Medicine, Northern Heart Hospital, Penang, Malaysia.
  • RSUD Dr. Soetomo General Academic Hospital, Surabaya, Indonesia.

ORCID-Profile: Bayushi Eka Putra, Yutaka Tadano, Umihiko Kaneko, Shoichi Kuramitsu, Tsutomu Fujita

Zitieren

APA

Putra, B. E., Tadano, Y., Kaneko, U., Sundarajoo, M., Pratama, I. S., Sugie, T., Kuramitsu, S., Kanno, D., Kashima, Y., & Fujita, T. (2026). A Simple Approach for 3D IVUS‐Angiographic Co‐Registration for CTOs Using the “Be‐The‐Wire” Cognitive Model. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70371

Vancouver

Putra BE, Tadano Y, Kaneko U, Sundarajoo M, Pratama IS, Sugie T, et al. A Simple Approach for 3D IVUS‐Angiographic Co‐Registration for CTOs Using the “Be‐The‐Wire” Cognitive Model. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70371

BibTeX
@article{Putra2026,
  author = {Putra, Bayushi Eka and Tadano, Yutaka and Kaneko, Umihiko and Sundarajoo, Mugilan and Pratama, Ivan Satria and Sugie, Takuro and Kuramitsu, Shoichi and Kanno, Daitaro and Kashima, Yoshifumi and Fujita, Tsutomu},
  title = {A Simple Approach for 3D IVUS‐Angiographic Co‐Registration for CTOs Using the “Be‐The‐Wire” Cognitive Model},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70371}
}
Kostenlos starten →