EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Intentional Stent Fracture to Accommodate Growth After Coarctation Stenting in an 860‐g Neonate

Magdalena Cuman, Gernot Buheitel, Peter Ewert, Stanimir Georgiev iD

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70291 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Magdalena Cuman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Munich, Lazarettstraße, Munich, Germany. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Aortic Coarctation, Stents. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Congenital aortic coarctation in neonates and children can be managed with transcatheter stent implantation, but this approach raises the issue of how to accommodate the fixed stent structure within the growing vessel. Case Summary A 15‐month‐old boy, born prematurely with critical aortic coarctation, was treated at 1 week of age with the implantation of a coronary stent. Subsequently, multiple stent dilatations were needed to adapt it to the growing aortic vessel. At 3 months the patient underwent balloon dilation with the simultaneous implantation of a second stent, and after 1 year an ultra‐high‐pressure balloon dilatation with intentional fracture of the coronary stent was performed.

Discussion

To overcome the problem of stenting a growing vessel, intentional stent fracture (ISF) with ultrahigh‐pressure (UHP) balloon has been introduced and applied in a limited number of patients. In piglet models, the ISF technique was associated with a significant incidence of complications, which were preventable (with the exception of stent fragment embolization) by performing pre‐stenting before ISF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Angioplasty, BalloonAortic CoarctationStentsHumansInfantInfant, NewbornMaleAortographyInfant, PrematureProsthesis DesignTreatment Outcome

Stichwörter der Autor:innen

napkin‐ring configurationneonatal aortic coarctationstent cracking/intentional stent fracture

Autor:innen und Institutionen

  • Department of Pediatric Cardiology and Congenital Heart Disease, German Heart Center Munich, Lazarettstraße, Munich, Germany.
  • Department of Pediatric Cardiology and Congenital Heart Disease, University Hospital Augsburg, Stenglinstraße, Augsburg, Germany.

ORCID-Profile: Stanimir Georgiev

Zitieren

APA

Cuman, M., Buheitel, G., Ewert, P., & Georgiev, S. (2026). Intentional Stent Fracture to Accommodate Growth After Coarctation Stenting in an 860‐g Neonate. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70291

Vancouver

Cuman M, Buheitel G, Ewert P, Georgiev S. Intentional Stent Fracture to Accommodate Growth After Coarctation Stenting in an 860‐g Neonate. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70291

BibTeX
@article{Cuman2026,
  author = {Cuman, Magdalena and Buheitel, Gernot and Ewert, Peter and Georgiev, Stanimir},
  title = {Intentional Stent Fracture to Accommodate Growth After Coarctation Stenting in an 860‐g Neonate},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70291}
}
Kostenlos starten →