Obstacles in Screening Below‐the‐Knee Arterial Lesions in CLTI Patients Using Doppler Ultrasound
Catheterization and Cardiovascular Interventions · 2026
DOI: 10.1002/ccd.70288 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Tomofumi Tsukizawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Nozaki Tokushukai Hospital, Osaka, Japan. Hauptthemen laut MEDLINE: Peripheral Arterial Disease, Ultrasonography, Doppler, Duplex, Ischemia, Lower Extremity. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
Background
Duplex ultrasound (DUS) is a noninvasive imaging modality increasingly used for the evaluation of lower extremity arterial disease. However, its diagnostic accuracy in below‐the‐knee (BTK) arteries among patients with chronic limb‐threatening ischemia (CLTI) remains uncertain. This study aimed to evaluate the diagnoticic accuracy of DUS for detecting BTK artery lesions in patients with CLTI by comparing its findings with angiography.
Aims
This study aimed to evaluate the diagnostic accuracy of duplex DUS for detecting BTK arterial lesions in patients with CLTI by comparing its findings with angiography.
Methods
We retrospectively analyzed 233 newly diagnosed CLTI patients (Rutherford grades 4–6) treated between 2018 and 2022. DUS findings were compared with angiographic findings in femoropopliteal arteries (FPA) and BTK arteries. The primary outcome was concordance between DUS and angiography. Secondary analyses identified clinical factors influencing concordance.
Results
The concordance rate for FPA was 82.0%, while BTK arteries showed significantly lower concordance: anterior tibial artery 52.9%, posterior tibial artery 58.6%, and peroneal artery 59.9% (all p < 0.001 vs. FPA). Factors associated with reduced concordance included older age, lean BMI, renal failure on dialysis, and FPA stenosis.
Conclusions
DUS demonstrates limited reliability in screening BTK lesions among CLTI patients, particularly in elderly or dialysis‐dependent populations. Given these limitations, angiography should be performed to confirm DUS findings in high‐risk groups to avoid underestimation of disease severity and inappropriate revascularization strategies. Recognizing key predictors of reduced DUS accuracy may help clinicians identify cases requiring confirmatory imaging and improve individualized diagnostic pathways in CLTI management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Nozaki Tokushukai Hospital, Osaka, Japan.
- Department of Diabetes Care Medicine, Osaka University Graduate School of Medicine, Osaka, Japan.
- Department of Clinical Engineering, Nozaki Tokushukai Hospital, Osaka, Japan.
ORCID-Profile: Tomofumi Tsukizawa
Zitieren
APA
Tsukizawa, T., Takahara, M., Yazu, Y., & Fujihara, M. (2026). Obstacles in Screening Below‐the‐Knee Arterial Lesions in CLTI Patients Using Doppler Ultrasound. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70288
Vancouver
Tsukizawa T, Takahara M, Yazu Y, Fujihara M. Obstacles in Screening Below‐the‐Knee Arterial Lesions in CLTI Patients Using Doppler Ultrasound. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70288
BibTeX
@article{Tsukizawa2026,
author = {Tsukizawa, Tomofumi and Takahara, Mitsuyoshi and Yazu, Yuko and Fujihara, Masahiko},
title = {Obstacles in Screening Below‐the‐Knee Arterial Lesions in CLTI Patients Using Doppler Ultrasound},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
doi = {10.1002/ccd.70288}
}
EUVIMED