Stiffness Parameters of the Radial Artery in Patients Undergoing Distal Transradial Coronary Angiography: A Duplex Ultrasonography Investigation
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70211 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Elton Soydan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Ege University Medical School, Izmir, Turkey. Hauptthemen laut MEDLINE: Radial Artery, Coronary Angiography, Catheterization, Peripheral, Cardiac Catheterization. Die Arbeit nennt 12 Literaturangaben. Gefördert von: The study has been accepted as a scientific research project and received financial support from the local scientific research projects fund (No 20677)..
Abstract (Originalsprache)
Background
Distal radial artery (DRA) is a feasible access in coronary angiography.
Aims
We aimed to determine the stiffness parameters of DRA and main radial artery (MRA) in pre and post‐transradial catheterization by using ultrasonography.
Methods
Patients admitted for elective distal transradial coronary angiography were consecutively enrolled from September to December 2020. Overall, Duplex analysis was assessed in 100 patients on admission and 24 h post‐catheterization. Emerging two MRA occlusion and four DRA occlusion cases were excluded from statistical analysis. As a result, we had 98 measurements in MRA and 96 in the DRA adjusted for statistical analysis.
Results
Systolic diameter of the DRA was smaller than the MRA as 2.21 ± 0.38 versus 2.38 ± 0.38 mm ( p group < 0.001). These increased to 2.4 ± 0.46 and 2.75 ± 0.47 mm, respectively, following catheterization ( p group‐time = 0.006). Stiffness index of the DRA was higher than the MRA (30.3 ± 26.3 vs. 22.7 ± 25.1 p = 0.601). After catheterization, this parameter significantly increased in the MRA while being preserved in the DRA ( p time‐group 0.032). Inversely, distensibility showed a decrease in the MRA ( p time‐grou p = 0.001) with preservation in the DRA after catheterization ( p = 0.422).
Conclusion
DRA is smaller and shows higher stiffness index with lower distensibility than the MRA. Following catheterization, these parameters show preservation in the DRA, despite an impairment in the MRA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Ege University Medical School, Izmir, Turkey.
ORCID-Profile: Elton Soydan, Mustafa Akın
Förderung
- The study has been accepted as a scientific research project and received financial support from the local scientific research projects fund (No 20677).
Zitieren
APA
Soydan, E., & Akın, M. (2025). Stiffness Parameters of the Radial Artery in Patients Undergoing Distal Transradial Coronary Angiography: A Duplex Ultrasonography Investigation. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70211
Vancouver
Soydan E, Akın M. Stiffness Parameters of the Radial Artery in Patients Undergoing Distal Transradial Coronary Angiography: A Duplex Ultrasonography Investigation. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70211
BibTeX
@article{Soydan2025,
author = {Soydan, Elton and Akın, Mustafa},
title = {Stiffness Parameters of the Radial Artery in Patients Undergoing Distal Transradial Coronary Angiography: A Duplex Ultrasonography Investigation},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70211}
}
EUVIMED