Feasibility and Safety of a Three‐Dimensional Sheath for Right Ventricular Septal Endomyocardial Biopsy
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70064 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Francesco Notaristefano und 16 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, University Hospital of Perugia, Perugia, Italy. Hauptthemen laut MEDLINE: Myocardium, Cardiac Catheterization, Ventricular Septum, Heart Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Background
Endomyocardial biopsy (EMB) is a complementary invasive procedure for the diagnosis of several cardiac diseases. New technical developments are needed to increase the safety of the procedure even in low‐volume centers.
Methods
We retrospectively enrolled patients who underwent EMB in our institution, which is a non‐heart transplant tertiary care center. Patients were divided into two groups according to the use of a standard long sheath (S‐T) or a three‐dimensional sheath (3D‐T). The latter was originally designed for conduction system pacing.
Results
There were 30 patients in the S‐T group and 16 in the 3D‐T group. Patients in the 3D‐T group were older (65 ± 19 vs. 52 ± 20, p = 0.049) and more likely to have ischaemic heart disease (25% vs. 0%, p = 0.011). Indications for EMB were similar in both groups except for a higher proportion of amyloidosis in the 3D‐T group (56% vs. 17%, p = 0.005). The total number of collected samples (10 ± 2 vs. 11 ± 3), their dimensions (1.3 ± 0.6 mm x 1 ± 0.3 mm vs. 1.7 ± 0.6 mm x 1.2 ± 0.4 mm) and the proportion of specimens meeting the quality standard to be analyzed (76% ± 26% vs. 83% ± 25%) didn't differ between 3D‐T and S‐T (all p = ns). Pericardial effusion or cardiac tamponade was more frequent in the S‐T group compared to the 3D‐T group (23% vs. 0%, p = 0.078). There were five cardiac tamponades in the S‐T group and none in the 3D‐T group.
Conclusion
The use of a 3D sheath for EMB of the right ventricular septum was feasible and safe with similar diagnostic accuracy compared to the standard long sheath technique.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Cardiology Department, University Hospital of Perugia, Perugia, Italy.
- Cardiovascular Pathophysiology Department, University Hospital of Perugia, Perugia, Italy.
- IRCCS San Raffaele Scientific Institute, Milan, Italy.
- Cardiovascular Pathology, University of Padua, Padua, Italy.
ORCID-Profile: Francesco Notaristefano, Erberto Carluccio
Zitieren
APA
Notaristefano, F., Catania, F., Del Papa, M., Freschini, M., Russo, G., Barengo, A., D'Ammando, M., Notaristefano, S., Sforna, S., De Gaspari, M., Rizzo, S., Zingarini, G., Verdecchia, P., Cavallini, C., Basso, C., Carluccio, E., & Sclafani, R. (2025). Feasibility and Safety of a Three‐Dimensional Sheath for Right Ventricular Septal Endomyocardial Biopsy. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70064
Vancouver
Notaristefano F, Catania F, Del Papa M, Freschini M, Russo G, Barengo A, et al. Feasibility and Safety of a Three‐Dimensional Sheath for Right Ventricular Septal Endomyocardial Biopsy. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70064
BibTeX
@article{Notaristefano2025,
author = {Notaristefano, Francesco and Catania, Francesco and Del Papa, Marco and Freschini, Manuel and Russo, Giovanni and Barengo, Alberto and D'Ammando, Matteo and Notaristefano, Salvatore and Sforna, Stefano and De Gaspari, Monica and Rizzo, Stefania and Zingarini, Gianluca and Verdecchia, Paolo and Cavallini, Claudio and Basso, Cristina and Carluccio, Erberto and Sclafani, Rocco},
title = {Feasibility and Safety of a Three‐Dimensional Sheath for Right Ventricular Septal Endomyocardial Biopsy},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70064}
}
EUVIMED