Re‐Exploration of Flow Rate in Low‐Flow, Low‐Gradient Aortic Stenosis
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70029 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Sara Hungerford und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Royal North Shore Hospital, Sydney, Australia. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Echocardiography, Stress, Ventricular Function, Left, Hemodynamics. Die Arbeit nennt 6 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Dr Sara Hungerford is supported by the National Heart Foundation of Australia Post-Doctoral Scholarship and Vanguard Award..
Abstract (Originalsprache)
Background
Transaortic flow rate (TFR, mL/s) is an emerging hemodynamic index in aortic stenosis (AS), offering insights beyond stroke volume index (SVi). We evaluated the hemodynamic determinants and prognostic significance of TFR at rest and peak dobutamine stress in patients with suspected low‐flow, low‐gradient (LF‐LG) AS and reduced left ventricular ejection fraction (LVEF < 50%).
Aims
This study aimed to assess and compare the hemodynamic determinants of TFR at rest and during peak pharmacological stress, and to evaluate their association with 3‐year survival.
Methods
Among 86 patients undergoing dobutamine stress echocardiography (DSE), 34 were classified as true severe, eight as pseudo‐severe, and 44 as indeterminate AS. TFR and associated parameters were assessed at rest and stress, and survival was evaluated at 3 years.
Results
At rest, no significant between‐group differences in TFR were observed ( p = 0.11). However, at peak stress, TFR differed significantly between groups: true severe (226 ± 62 mL/s), pseudo‐severe (334 ± 55 mL/s), and indeterminate (248 ± 67 mL/s; p < 0.01). Rest TFR was independently associated with cardiac output (CO), arterial compliance, and valvulo‐arterial impedance (ZVA). During stress, TFR was predominantly associated with CO, although systemic vascular properties remained significant in pseudo‐severe AS. Flow reserve (ΔTFR) was influenced only by stress‐derived variables. At 3‐year follow‐up, stress TFR was a significant predictor of survival ( p = 0.03), independent of AS classification ( p = 0.04) and intervention ( p = 0.04). A stress TFR > 195 mL/s was the optimal survival threshold (AUC 0.64; sensitivity 85%, specificity 70%).
Conclusions
These findings suggest that stress TFR reflects left ventricular contractile reserve and carries prognostic value in LF‐LG AS. Stress‐based assessment may enhance clinical decision‐making, particularly in diagnostically ambiguous AS subsets.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, Royal North Shore Hospital, Sydney, Australia.
- Faculty of Health and Medicine, The University of Sydney, Sydney, Australia.
- The CardioVascular Center Tufts, Boston, Massachusetts, USA.
ORCID-Profile: Sara Hungerford, Eleanor Rye
Förderung
- Dr Sara Hungerford is supported by the National Heart Foundation of Australia Post-Doctoral Scholarship and Vanguard Award.
Zitieren
APA
Hungerford, S., Rye, E., Sritharan, H., Hansen, P., Choong, C., & Bhindi, R. (2025). Re‐Exploration of Flow Rate in Low‐Flow, Low‐Gradient Aortic Stenosis. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70029
Vancouver
Hungerford S, Rye E, Sritharan H, Hansen P, Choong C, Bhindi R. Re‐Exploration of Flow Rate in Low‐Flow, Low‐Gradient Aortic Stenosis. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70029
BibTeX
@article{Hungerford2025,
author = {Hungerford, Sara and Rye, Eleanor and Sritharan, Hari and Hansen, Peter and Choong, Christopher and Bhindi, Ravinay},
title = {Re‐Exploration of Flow Rate in Low‐Flow, Low‐Gradient Aortic Stenosis},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70029}
}