Serial Changes in Right Ventricular Outflow Tract Gradient and Endocarditis Risk After Transcatheter Pulmonary Valve Replacement
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70027 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Juan C Samayoa und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Division of Cardiology, University of Minnesota Masonic Children's Hospital, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Pulmonary Valve, Heart Valve Prosthesis Implantation, Heart Valve Prosthesis, Cardiac Catheterization. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Infective endocarditis (IE) after transcatheter pulmonary valve replacement (TPVR) remains a significant concern. Although there are overall good short‐term and long‐term hemodynamic outcomes, limited data exist comparing postimplantation echocardiographic findings leading to IE.
Objectives
To compare the progressive echocardiographic performance of percutaneous implanted pulmonary valves before the development of IE.
Methods
This is a single‐center retrospective cohort study of all patients who underwent successful TPVR using either Medtronic Melody or Edwards Sapien valves from 2009 to 2021. Patient demographics, procedural details, and yearly echocardiographic findings were collected and compared as appropriate. The risk of IE was compared between groups defined by baseline characteristics using time‐to‐event methods. Joint modeling was used to evaluate the association between peak‐to‐peak gradient trajectories over time and the risk of IE. The predictive performance of using peak‐to‐peak gradient thresholds to predict IE was evaluated using receiver operating characteristic (ROC) analyses.
Result
A total of 226 patients underwent successful TPVR of which 26 patients developed IE. The annualized incidence of IE was 2.96 per 100 patient years. Patients with and without IE had similar ages, weights, and diagnoses. All IE cases were with the Melody valves. Patients who had higher postimplantation echo‐derived peak instantaneous gradients (PGs) were significantly more likely to develop IE. Patients with immediate postimplant invasive peak to peak gradient ≥ 15 mmHg were more likely to develop IE. Higher PGs over time were significantly associated with a higher risk of IE (HR 1.04 per mmHg; 95% CI: 1.00−1.07, p = 0.03). ROC analyses indicate that PGs over time have poor predictive performance of IE.
Conclusion
Echocardiographic performance following TPVR was generally acceptable and similar to other studies. Patients who ultimately developed IE trended to have higher PPG post‐TPVR and higher gradients over time before the development of IE. The rate of change of echo‐derived gradients in patients with lower initial invasive gradients was more pronounced. These findings suggest that longitudinal monitoring of echocardiographic gradient could provide targeted surveillance in those identified at higher risk for IE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatrics, Division of Cardiology, University of Minnesota Masonic Children's Hospital, Minneapolis, Minnesota, USA.
- Department of Pediatrics, Heart Institute, UPMC Children's Hospital of Pittsburgh, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA.
- Department of Pediatrics, Division of Cardiology, Seattle Children's Hospital, University of Washington, Seattle, Washington, USA.
- Department of Biostatistics, University of Washington, Seattle, Washington, USA.
- Department of Biostatistics and Health Data Science, University of Minnesota, Minneapolis, Minnesota, USA.
- Department of Internal Medicine, Division of Cardiology, University of Washington Medical Center, Seattle, Washington, USA.
ORCID-Profile: Juan C Samayoa, Lauren Carlozzi, Connie Choi, Benjamin Langworthy, Zachary L Steinberg
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Samayoa, J. C., Carlozzi, L., Choi, C., Tressel, W., Wolf, J. M., Langworthy, B., Rubio, A., Johnston, T., Steinberg, Z. L., Jones, T., & Morray, B. (2025). Serial Changes in Right Ventricular Outflow Tract Gradient and Endocarditis Risk After Transcatheter Pulmonary Valve Replacement. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70027
Vancouver
Samayoa JC, Carlozzi L, Choi C, Tressel W, Wolf JM, Langworthy B, et al. Serial Changes in Right Ventricular Outflow Tract Gradient and Endocarditis Risk After Transcatheter Pulmonary Valve Replacement. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70027
BibTeX
@article{Samayoa2025,
author = {Samayoa, Juan C and Carlozzi, Lauren and Choi, Connie and Tressel, William and Wolf, Jack M and Langworthy, Benjamin and Rubio, Agustin and Johnston, Troy and Steinberg, Zachary L and Jones, Thomas and Morray, Brian},
title = {Serial Changes in Right Ventricular Outflow Tract Gradient and Endocarditis Risk After Transcatheter Pulmonary Valve Replacement},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70027}
}
EUVIMED