EUVIMEDEUVIMED entdecken
Fallbericht

Emergency Transcatheter Aortic Valve in Sutureless Valve Replacement for Managing Cardiogenic Shock

Alessandro Comis iD, Sebastiano Immè, Claudia Tamburino, Corrado Tamburino

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31717 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Alessandro Comis und 3 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology unit, Policlinico Centro Cuore Morgagni, Pedara, Italy. Hauptthemen laut MEDLINE: Shock, Cardiogenic, Heart Valve Prosthesis, Aortic Valve, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sutureless aortic bioprosthesis (SBVs) may pose specific challenges to valve‐in‐valve (ViV) implantation, particularly, in the setting of cardiogenic shock which remains challenging and understudied. We report the case of a 69‐year‐old man with a SBVs disfunction, presenting with acute decompensated HF. Despite intra‐aortic balloon pump (IABP), clinical deterioration prompted an emergency transcatheter ViV. Computer tomography imaging confirmed procedural feasibility. A self‐expanding Evolut PRO+ valve was deployment followed by post‐dilatation for underexpansion. The procedure restored valve function, and the patient was weaned off IABP. At 30‐day follow‐up, patient was in NYHA class I with complete recovery of left ventricular systolic function. This is the first reported case of emergency ViV for a degenerated sutureless valve. Careful CT planning and device selection are critical. Despite the lack of data in this setting, ViV may represent a safe and effective option for high‐risk patients in cardiogenic shock.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Shock, CardiogenicHeart Valve ProsthesisAortic ValveTranscatheter Aortic Valve ReplacementBioprosthesisAortic Valve StenosisHeart Valve Prosthesis ImplantationSutureless Surgical ProceduresProsthesis FailureHumansAgedMaleTreatment OutcomeProsthesis DesignVentricular Function, LeftEmergenciesRecovery of FunctionIntra-Aortic Balloon Pumping

Autor:innen und Institutionen

  • Cardiology unit, Policlinico Centro Cuore Morgagni, Pedara, Italy.
  • University of Catania, Catania, Italy.

ORCID-Profile: Alessandro Comis

Zitieren

APA

Comis, A., Immè, S., Tamburino, C., & Tamburino, C. (2025). Emergency Transcatheter Aortic Valve in Sutureless Valve Replacement for Managing Cardiogenic Shock. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31717

Vancouver

Comis A, Immè S, Tamburino C, Tamburino C. Emergency Transcatheter Aortic Valve in Sutureless Valve Replacement for Managing Cardiogenic Shock. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31717

BibTeX
@article{Comis2025,
  author = {Comis, Alessandro and Immè, Sebastiano and Tamburino, Claudia and Tamburino, Corrado},
  title = {Emergency Transcatheter Aortic Valve in Sutureless Valve Replacement for Managing Cardiogenic Shock},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31717}
}
Kostenlos starten →