Procedural Factors Associated With High Radiation Exposure During Percutaneous Coronary Intervention
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31606 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Yuyang Ye und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Center for High Altitude Medicine, West China Hospital, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Percutaneous Coronary Intervention, Radiation Exposure, Radiation Dosage, Radiography, Interventional. Die Arbeit nennt 22 Literaturangaben. Gefördert von: This study was supported by grant GYYX24006 from 1•3•5 Project of Center for High Altitude Medicine, West China Hospital, Sichuan University..
Abstract (Originalsprache)
Background and Aims An air kerma (AK) radiation dose of 5 Gy is considered a threshold that may result in clinically significant radiation injury during percutaneous coronary intervention (PCI). This study aimed to identify procedural characteristics associated with patient AK ≥ 5 Gy during PCI.
Methods
This retrospective study included consecutive PCI procedures performed at West China Hospital between July 30, 2018, and October 31, 2021. Descriptive analysis was conducted to explore associations between baseline characteristics and high radiation doses. Multivariate logistic regression was used to identify procedural predictors of AK ≥ 5 Gy, and a receiver operating characteristic (ROC) curve was applied to assess the model's predictive performance.
Results
A total of 8444 PCI procedures were analyzed. Multivariate logistic regression identified the following procedural predictors of AK ≥ 5 Gy: number of stents implanted (odds ratio [OR]: 1.67; 95% CI: 1.50–1.87), PCI involving left circumflex coronary artery (OR: 1.58; 95% CI: 1.18–2.10), use of intra‐aortic ballon pump (OR: 1.91; 95% CI: 1.18–2.99), use of intravascular ultrasound (OR: 1.67; 95% CI: 1.31–2.14), PCI of in‐stent restenosis (OR: 2.14; 95% CI: 1.36–3.28), and PCI of chronic total occlusion (OR: 3.40; 95% CI: 2.72–4.24). The area under the ROC curve for the logistic regression model was 0.795, with a specificity of 78.3% and a sensitivity of 67.4%.
Conclusion
Specific procedural characteristics are associated with AK ≥ 5 Gy during PCI. Identifying these risk factors may help optimize radiation safety strategies and minimize patient exposure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Center for High Altitude Medicine, West China Hospital, Sichuan University, Chengdu, China.
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
ORCID-Profile: Yiming Li
Förderung
- This study was supported by grant GYYX24006 from 1•3•5 Project of Center for High Altitude Medicine, West China Hospital, Sichuan University.
Zitieren
APA
Ye, Y., Zhou, X., Li, Y., Bai, L., Wang, J., Chen, X., Hu, X., & Peng, Y. (2025). Procedural Factors Associated With High Radiation Exposure During Percutaneous Coronary Intervention. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31606
Vancouver
Ye Y, Zhou X, Li Y, Bai L, Wang J, Chen X, et al. Procedural Factors Associated With High Radiation Exposure During Percutaneous Coronary Intervention. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31606
BibTeX
@article{Ye2025,
author = {Ye, Yuyang and Zhou, Xuan and Li, Yiming and Bai, Lin and Wang, Junwen and Chen, Xuefeng and Hu, Xinru and Peng, Yong},
title = {Procedural Factors Associated With High Radiation Exposure During Percutaneous Coronary Intervention},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31606}
}
EUVIMED