Diagnostic Performance of Angiography‐Based Vessel‐Fractional Flow Reserve Compared with Various Wire‐Based Physiological Assessments
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31534 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Asahi Oshima und 13 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Coronary Angiography, Cardiac Catheterization, Coronary Artery Disease. Die Arbeit nennt 28 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Although considered the gold standard, pressure wire‐derived fractional flow reserve (PW‐FFR) and instantaneous wave‐free ratio (PW‐iFR) are not sufficiently adopted. Vessel fractional flow reserve (vFFR) is a potentially less invasive surrogate.
Aims
To validate the diagnostic performance of vFFR against the wire‐based physiological assessments in real‐world clinical settings.
Methods
In this single‐center retrospective study, we analyzed 479 patients (586 vessels) who underwent PW‐FFR and vFFR in the same vessel, and evaluated the correlation between vFFR and PW‐FFR using PW‐FFR ≦ 0.80 as the reference. Additionally, we analyzed 378 patients (455 vessels) with vFFR, PW‐FFR, and PW‐iFR, and 93 patients (119 vessels) with vFFR, PW‐FFR, and resting full‐cycle ratio (RFR).
Results
The indications for coronary angiography were stable angina (92%), unstable angina (6.3%), and non‐ST‐elevation myocardial infarction (1.5%). The target vessels were the left anterior descending artery (61%), left circumflex artery (20%), and right coronary artery (19%). A good correlation was found between vFFR and PW‐FFR ( R = 0.67; p < 0.001) with a mean bias of 0.0068 ± 0.0786. vFFR demonstrated good accuracy at predicting PW‐FFR ≦0.80 (area under the curve [AUC] = 0.86; 95% confidence interval [CI]: 0.83‐0.89). At a vFFR cut‐off value of ≦0.80, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for predicting PW‐FFR ≦0.80 were 78.8%, 82.5%, 77.6%, 83.5%, and 80.9%, respectively, with a Cohen's Kappa coefficient of 0.612. Similar results were observed for vFFR with PW‐iFR and RFR. Conclusion vFFR demonstrated good correlation and diagnostic performance compared with wire‐based physiological assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan.
- CORRIB Research Center for Advanced Imaging and Core lab, School of Medicine, University of Galway, Galway, Ireland.
- Division of Cardiology, Department of Internal Medicine, Iwate Medical University, Iwate, Japan.
- Department of Cardiovascular Medicine, Gunma University Graduate School of Medicine, Maebashi, Japan.
ORCID-Profile: Asahi Oshima, Patrick W Serruys, Masahiko Asami
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Oshima, A., Ninomiya, K., Sekiguchi, M., Yoshiura, D., Gonda, Y., Horiuchi, Y., Taniwaki, M., Yuzawa, H., Komiyama, K., Tanaka, J., Onuma, Y., Serruys, P. W., Tanabe, K., & Asami, M. (2025). Diagnostic Performance of Angiography‐Based Vessel‐Fractional Flow Reserve Compared with Various Wire‐Based Physiological Assessments. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31534
Vancouver
Oshima A, Ninomiya K, Sekiguchi M, Yoshiura D, Gonda Y, Horiuchi Y, et al. Diagnostic Performance of Angiography‐Based Vessel‐Fractional Flow Reserve Compared with Various Wire‐Based Physiological Assessments. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31534
BibTeX
@article{Oshima2025,
author = {Oshima, Asahi and Ninomiya, Kai and Sekiguchi, Masahiro and Yoshiura, Daiki and Gonda, Yuki and Horiuchi, Yu and Taniwaki, Masanori and Yuzawa, Hitomi and Komiyama, Kota and Tanaka, Jun and Onuma, Yoshinobu and Serruys, Patrick W and Tanabe, Kengo and Asami, Masahiko},
title = {Diagnostic Performance of Angiography‐Based Vessel‐Fractional Flow Reserve Compared with Various Wire‐Based Physiological Assessments},