Paclitaxel‐Coated Balloon for the Management of In‐Stent Coronary Restenosis: An Updated Meta‐Analysis and Trial Sequential Analysis
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31388 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Vinícius M R Oliveira und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Federal University of Goiás, Goiânia, Brazil. Hauptthemen laut MEDLINE: Paclitaxel, Cardiovascular Agents, Coronary Restenosis, Coated Materials, Biocompatible. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Drug‐coated balloons present a potentially advantageous therapeutic approach for managing coronary in‐stent restenosis (ISR). However, the comparative benefits of paclitaxel‐coated balloons (PCBs) over uncoated balloons (UCBs) remain unclear.
Aims
We conducted a systematic review and meta‐analysis to evaluate and compare the clinical outcomes of patients treated with PCBs and UCBs.
Methods
We systematically searched PubMed, Embase, and Cochrane for studies comparing PCBs and UCBs in managing coronary ISR. We used a random‐effects model to pool risk ratios (RRs) and their 95% confidence intervals (CIs). Statistical analyses were conducted using Review Manager 5.4.1. Heterogeneity was assessed using I 2 statistics. Quality and risk of bias were evaluated using the Cochrane Collaboration's tool.
Results
We included seven randomized controlled trials with 1349 patients, of whom 840 underwent percutaneous coronary intervention with PCB. In our pooled analysis, patients treated with PCB had lower risks of target lesion revascularization (RR 0.31, 95% CI 0.18–0.52; p < 0.01), target vessel revascularization (0.53, 0.42–0.67; p < 0.01), major adverse cardiac events (MACEs) (0.25, 0.16–0.38; p < 0.01), and myocardial infarction (MI) (0.59, 0.37–0.95; p = 0.03). However, there were no significant differences in all‐cause mortality (0.79, 0.37–1.70; p = 0.54), cardiac death (0.46, 0.03–8.12; p = 0.60), while tendencies for a significant difference were found for target lesion failure (0.39, 0.13–1.11; p = 0.08), or stent thrombosis (0.21, 0.03–1.35 p = 0.10).
Conclusion
These findings suggest that PCBs are superior to UCBs regarding the occurrence of target lesion revascularization, target vessel revascularization, MACEs, and MI, but they do not differ in all‐cause mortality, and cardiac death, while trends to significant differences favoring PCB were found to stent thrombosis and target lesion failure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medicine, Federal University of Goiás, Goiânia, Brazil.
- Department of Medicine, State University of Campinas, Campinas, Brazil.
- Hospital Israelita Albert Einstein, São Paulo, Brazil.
ORCID-Profile: Humberto Graner Moreira
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Oliveira, V. M. R., Paiva, A. M., Alencar, P. L. A., Oliveira, I. C., Alencar, J. V. A., Zalaf, F. S., Piai, R. F. P., de Sousa, A. M., & Moreira, H. G. (2025). Paclitaxel‐Coated Balloon for the Management of In‐Stent Coronary Restenosis: An Updated Meta‐Analysis and Trial Sequential Analysis. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31388
Vancouver
Oliveira VMR, Paiva AM, Alencar PLA, Oliveira IC, Alencar JVA, Zalaf FS, et al. Paclitaxel‐Coated Balloon for the Management of In‐Stent Coronary Restenosis: An Updated Meta‐Analysis and Trial Sequential Analysis. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31388
BibTeX
@article{Oliveira2025,
author = {Oliveira, Vinícius M R and Paiva, Arthur Marot and Alencar, Pedro Lucas Alves and Oliveira, Izadora Caiado and Alencar, João Victor Alves and Zalaf, Felipe Schmaltz and Piai, Ricardo Figueiredo Paro and de Sousa, André Maroccolo and Moreira, Humberto Graner},
title = {Paclitaxel‐Coated Balloon for the Management of In‐Stent Coronary Restenosis: An Updated Meta‐Analysis and Trial Sequential Analysis},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31388}
}
EUVIMED