Predictors of permanent pacemaker implantation for transcatheter self‐expandable aortic valve implant in the cusp overlap era
Catheterization and Cardiovascular Interventions · 2024
DOI: 10.1002/ccd.31176 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2024. Verfasst von Oscar A Mendiz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Interventional Cardiology Department, Cardiology and Cardiovascular Surgery Institute (ICCYC), Hospital Universitario Fundación Favaloro, Buenos Aire…. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Pacemaker, Artificial, Aortic Valve Stenosis, Prosthesis Design. Die Arbeit nennt 22 Literaturangaben.
Abstract (Originalsprache)
Background
Predictors of permanent pacemaker implantation (PPMI) after self‐expanding transcatheter aortic valve implant (TAVI) were described. Is unknown if PPMI predictors remain in the era of high implants using the cusp overlap (COP).
Methods
Single‐center, prospective, consecutive case series of patients undergoing self‐expanding TAVI with the COP approach. The status of PPMI and other clinical events were ascertained at 30 days.
Results
A total of 261 patients were included (84% with Evolut, n = 219). Implant depth >4 mm was infrequent (13.8%). TAVI depth (OR 1.259; p = 0.005), first or second‐degree auriculo‐ventricular block (OR 3.406; p = 0.033), right‐bundle (OR 15.477; p < 0.0001), and incomplete left‐bundle branch block (OR 7.964; p = 0.036) were found to be independent predictors of PPMI. The risk of PPMI with deep implant and no electrical disturbances was 3%, and 0% with high implant and no prior electrical disturbances. Those who received PPMI had no statistically significant increased risk of death, myocardial infarction, stroke, bleeding events, or vascular complications at 30 days, but longer hospital stay (mean difference 1.43 days more, p = 0.003).
Conclusions
Implant depth and prior conduction abnormalities remain the main predictors of PPMI using self‐expanding TAVI in the COP era. Patients with high implants and no prior conduction abnormalities may be candidates for early discharge after uneventful self‐expanding TAVI, while the rest may need inpatient monitoring regardless of achieving a high implant. The need for PPMI was associated with longer hospital stays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Interventional Cardiology Department, Cardiology and Cardiovascular Surgery Institute (ICCYC), Hospital Universitario Fundación Favaloro, Buenos Aires, Argentina.
- Cardiology Department, Hospital Universitario Fundación Favaloro, Buenos Aires, Argentina.
- Health Research Methods, Evidence, and Impact, McMaster University, Hamilton, Ontario, Canada.
ORCID-Profile: Oscar A Mendiz, Pablo Lamelas
Zitieren
APA
Mendiz, O. A., Fava, C., Müller, L. I., Lev, G. A., Heredia, G., Gómez, S. E., Cedeño, J., Pérez, J. M., & Lamelas, P. (2024). Predictors of permanent pacemaker implantation for transcatheter self‐expandable aortic valve implant in the cusp overlap era. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31176
Vancouver
Mendiz OA, Fava C, Müller LI, Lev GA, Heredia G, Gómez SE, et al. Predictors of permanent pacemaker implantation for transcatheter self‐expandable aortic valve implant in the cusp overlap era. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31176
BibTeX
@article{Mendiz2024,
author = {Mendiz, Oscar A and Fava, Carlos and Müller, Lucas I and Lev, Gustavo A and Heredia, Gaston and Gómez, Silvina E and Cedeño, Joaquín and Pérez, Juan M and Lamelas, Pablo},
title = {Predictors of permanent pacemaker implantation for transcatheter self‐expandable aortic valve implant in the cusp overlap era},
journal = {Catheterization and Cardiovascular Interventions},
year = {2024},
doi = {10.1002/ccd.31176}
}
EUVIMED