EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY-NC-ND 4.0

Suture closure AFtEr large bore vein access (SAFE‐VEIN): A randomized, prospective study of the efficacy and safety of venous closure device

Mahmoud Ali, Faisal Masood, Lynn Erickson, James Adefisoye, Jim Kanani, Sara Walczak, Tarek Ajam, Andy Kieu, Mohammed Premjee, M Fuad Jan, Suhail Q Allaqaband iD, Tanvir Bajwa iD und 7 weitere

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.31173 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2024. Verfasst von Mahmoud Ali und 18 weiteren Autor:innen. Beteiligte Einrichtung: Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Aurora Health Care, Milwaukee, Wisconsin, USA. Hauptthemen laut MEDLINE: Suture Techniques, Punctures, Hemostatic Techniques, Hemorrhage. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Perclose ProGlide (PPG) Suture‐Mediated Closure System™ is safe and can reduce time to hemostasis following procedures requiring arterial access.

Aims

We aimed to compare PPG to figure of 8 suture in patients who underwent interventional catheter procedures requiring large bore venous access (LBVA) (≥13 French).

Methods

In this physician‐initiated, randomized, single‐center study [ clinicaltrials.gov ID: NCT04632641], single‐stick venous access was obtained under ultrasound guidance. Eligible patients were randomized 1:1, and 100 subjects received allocated treatment to either PPG ( n = 47) or figure of 8 suture ( n = 53). No femoral arterial access was used in any patient. Primary outcomes were time to achieve hemostasis (TTH) and time to ambulation (TTA). Secondary outcomes were time to discharge (TTD) and vascular‐related complications and mortality. Wilcoxon rank‐sum test was used to compare TTH, TTA, and TTD.

Results

TTH (minutes) was significantly lower in PPG versus figure of 8 suture [median, (Q1, Q3)] [7 (2,10) vs. 11 (10,15) respectively, p < 0.001]. TTA (minutes) was significantly lower in PPG compared to figure of 8 suture [322 (246,452) vs. 403 (353, 633) respectively, p = 0.005]. TTD (minutes) was not significantly different between the PPG and figure of 8 suture arms [1257 (1081, 1544) vs. 1338 (1171,1435), p = 0.650]. There was no difference in minor bleeding or access site hematomas between both arms. No other vascular complications or mortality were reported.

Conclusion

PPG use had lower TTH and TTA than figure of 8 suture in a population of patients receiving LBVA procedures. This may encourage same‐day discharge in these patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Suture TechniquesPuncturesHemostatic TechniquesHemorrhageCatheterization, PeripheralVascular Closure DevicesHumansMaleFemaleProspective StudiesTreatment OutcomeTime FactorsMiddle AgedAgedEquipment DesignRisk FactorsUltrasonography, InterventionalLength of Stay

Stichwörter der Autor:innen

SMCablationclosure devicehemostasislarge bore venous accessperclose proglide

Autor:innen und Institutionen

  • Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Aurora Health Care, Milwaukee, Wisconsin, USA.
  • Academic Affairs, Cardiovascular Research, Aurora Sinai/Aurora St. Luke's Medical Centers, Aurora Health Care, Milwaukee, Wisconsin, USA.
  • Academic Affairs, Aurora UW Medical Group, Center for Urban Population Health, Aurora Sinai Medical Center, Aurora Health Care, Milwaukee, Wisconsin, USA.
  • Division of Cardiovascular Medicine, University of Wisconsin School of Medicine and Public Health, Milwaukee Clinical Campus, Milwaukee, Wisconsin, USA.

ORCID-Profile: Suhail Q Allaqaband, Tanvir Bajwa, Jodi Zilinski, M Eyman Mortada

Zitieren

APA

Ali, M., Masood, F., Erickson, L., Adefisoye, J., Kanani, J., Walczak, S., Ajam, T., Kieu, A., Premjee, M., Jan, M. F., Allaqaband, S. Q., Bajwa, T., Khitha, J., Zilinski, J., Jahangir, A., Djelmami-Hani, M., Sra, J., Niazi, I., & Mortada, M. E. (2024). Suture closure AFtEr large bore vein access (SAFE‐VEIN): A randomized, prospective study of the efficacy and safety of venous closure device. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31173

Vancouver

Ali M, Masood F, Erickson L, Adefisoye J, Kanani J, Walczak S, et al. Suture closure AFtEr large bore vein access (SAFE‐VEIN): A randomized, prospective study of the efficacy and safety of venous closure device. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31173

BibTeX
@article{Ali2024,
  author = {Ali, Mahmoud and Masood, Faisal and Erickson, Lynn and Adefisoye, James and Kanani, Jim and Walczak, Sara and Ajam, Tarek and Kieu, Andy and Premjee, Mohammed and Jan, M Fuad and Allaqaband, Suhail Q and Bajwa, Tanvir and Khitha, Jayant and Zilinski, Jodi and Jahangir, Arshad and Djelmami-Hani, Mohamed and Sra, Jasbir and Niazi, Imran and Mortada, M Eyman},
  title = {Suture closure AFtEr large bore vein access (SAFE‐VEIN): A randomized, prospective study of the efficacy and safety of venous closure device},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.31173}
}
Kostenlos starten →