EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of thrombogenicity in different types of drug‐eluting stents during transition from DAPT to SAPT

Kenji Kawai iD, Yu Sato iD, Anne Cornelissen, Frank D Kolodgie, Qi Cheng, Rika Kawakami iD, Takao Konishi, Laura E L Perkins iD, Renu Virmani iD, Aloke V Finn iD

Catheterization and Cardiovascular Interventions · 2024-07 · 104 (1) · 10-20

DOI: 10.1002/ccd.31083 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 20.05.2024. Verfasst von Kenji Kawai und 9 weiteren Autor:innen. Beteiligte Einrichtung: CVPath Institute, Inc., Gaithersburg, Maryland. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Platelet Aggregation Inhibitors, Prosthesis Design, Clopidogrel. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: CVPath Institute, Abbott Vascular.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

During the transition from dual antiplatelet therapy (DAPT) to single antiplatelet therapy (SAPT), previous studies have raised concerns about a rebound effect. We compared platelet and inflammatory cell adhesion on different types of stents in the setting of clopidogrel presence and withdrawal.

Methods

In Experiment 1, three pigs were administered with DAPT, that is, clopidogrel and acetylsalicylic acid (ASA), for 7 days. Each animal underwent an extracorporeal carotid arteriovenous shunt model implanted with fluoropolymer‐coated everolimus‐eluting stent (FP‐EES), biodegradable‐polymer sirolimus‐eluting stent (BP‐SES), and biodegradable‐polymer everolimus‐eluting stents (BP‐EES). In Experiment 2, two pigs were administered DAPT, clopidogrel was then withdrawn at day 7, and SAPT with ASA was continued for next 21 days. Then flow‐loop experiments with the drawn blood from each time point were performed for FP‐EES, BioLinx‐polymer zotarolimus‐eluting stents (BL‐ZES), and BP‐EES. The rebound effect was defined as the statistical increase of inflammation and platelet adhesion assessed with immunohistochemistry on the stent‐strut level basis from baseline to day‐14 or 28.

Results

Both experiments showed platelet adhesion value was highest in BP‐EES, while the least in FP‐EES during DAPT therapy. There was no increase in platelet or inflammatory cell adhesion above baseline values (i.e., no therapy) due to the cessation of clopidogrel on the stent‐strut level. Monocyte adhesion was the least for FP‐EES with the same trend observed for neutrophil adhesion.

Conclusions

No evidence of rebound effect was seen after the transition from DAPT to SAPT. FP‐EES demonstrated the most favorable antithrombotic and anti‐inflammatory profile regardless of the different experimental designs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drug-Eluting StentsPlatelet Aggregation InhibitorsProsthesis DesignClopidogrelSirolimusDual Anti-Platelet TherapyEverolimusThrombosisAspirinPlatelet AdhesivenessAnimalsTime FactorsArteriovenous Shunt, SurgicalSus scrofaBlood PlateletsDrug Administration ScheduleDisease Models, Animal

Stichwörter der Autor:innen

coronary artery diseasedrug‐eluting stentdual antiplatelet therapyrebound effectsingle antiplatelet therapy

Substanzen

Platelet Aggregation InhibitorsClopidogrelSirolimusEverolimusAspirinzotarolimus

Autor:innen und Institutionen

  • CVPath Institute, Inc., Gaithersburg, Maryland.
  • Abbott Vascular, Santa Clara, California.
  • University of Maryland, Baltimore, Maryland.

ORCID-Profile: Kenji Kawai, Yu Sato, Rika Kawakami, Laura E L Perkins, Renu Virmani, Aloke V Finn

Förderung

  • CVPath Institute
  • Abbott Vascular

Zitieren

APA

Kawai, K., Sato, Y., Cornelissen, A., Kolodgie, F. D., Cheng, Q., Kawakami, R., Konishi, T., Perkins, L. E. L., Virmani, R., & Finn, A. V. (2024). Comparison of thrombogenicity in different types of drug‐eluting stents during transition from DAPT to SAPT. Catheterization and Cardiovascular Interventions, 104(1), 10-20. https://doi.org/10.1002/ccd.31083

Vancouver

Kawai K, Sato Y, Cornelissen A, Kolodgie FD, Cheng Q, Kawakami R, et al. Comparison of thrombogenicity in different types of drug‐eluting stents during transition from DAPT to SAPT. Catheterization and Cardiovascular Interventions. 2024;104(1):10-20. doi:10.1002/ccd.31083

BibTeX
@article{Kawai2024,
  author = {Kawai, Kenji and Sato, Yu and Cornelissen, Anne and Kolodgie, Frank D and Cheng, Qi and Kawakami, Rika and Konishi, Takao and Perkins, Laura E L and Virmani, Renu and Finn, Aloke V},
  title = {Comparison of thrombogenicity in different types of drug‐eluting stents during transition from DAPT to SAPT},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  volume = {104},
  number = {1},
  pages = {10--20},
  doi = {10.1002/ccd.31083}
}
Kostenlos starten →