EUVIMEDEUVIMED entdecken
FallberichtVideo/Audio

Novel valve‐in‐surgical bioprosthetic transcatheter aortic valve replacement: Undermining iatrogenic coronary obstruction with radiofrequency needle (UNICORN)

Cullen E Buchanan iD, Mina Iskander, Saif Anwaruddin, Peter J Mason

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.31038 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, 2024. Verfasst von Cullen E Buchanan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine-Cardiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Bioprosthesis, Iatrogenic Disease, Transcatheter Aortic Valve Replacement. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 6 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An 86‐year‐old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve‐in‐valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisBioprosthesisIatrogenic DiseaseTranscatheter Aortic Valve ReplacementAortic ValveAortic Valve StenosisProsthesis DesignHumansAged, 80 and overFemaleTreatment OutcomeCatheter AblationProsthesis FailureHeart Valve Prosthesis ImplantationHeart InjuriesNeedlesVentricular Function, LeftCoronary OcclusionCoronary Angiography

Stichwörter der Autor:innen

bioprosthetic valve dysfunction or prosthetic valve stenosisleaflet lacerationleaflet modificationvalve‐in‐valve transcatheter aortic valve replacement

Autor:innen und Institutionen

  • Department of Medicine-Cardiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.

ORCID-Profile: Cullen E Buchanan

Zitieren

APA

Buchanan, C. E., Iskander, M., Anwaruddin, S., & Mason, P. J. (2024). Novel valve‐in‐surgical bioprosthetic transcatheter aortic valve replacement: Undermining iatrogenic coronary obstruction with radiofrequency needle (UNICORN). Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31038

Vancouver

Buchanan CE, Iskander M, Anwaruddin S, Mason PJ. Novel valve‐in‐surgical bioprosthetic transcatheter aortic valve replacement: Undermining iatrogenic coronary obstruction with radiofrequency needle (UNICORN). Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31038

BibTeX
@article{Buchanan2024,
  author = {Buchanan, Cullen E and Iskander, Mina and Anwaruddin, Saif and Mason, Peter J},
  title = {Novel valve‐in‐surgical bioprosthetic transcatheter aortic valve replacement: Undermining iatrogenic coronary obstruction with radiofrequency needle (UNICORN)},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.31038}
}
Kostenlos starten →