EUVIMEDEUVIMED entdecken
Vergleichsstudie

Impact of vessel volume on thermodilution measurements in patients with coronary microvascular dysfunction

Koshiro Sakai, Tatyana Storozhenko, Takuya Mizukami, Hirofumi Ohashi, Frederic Bouisset, Atomu Tajima, Lieven van Hoe, Emanuele Gallinoro iD, Giulia Botti, Thabo Mahendiran, Sofie Pardaens, Sofie Brouwers und 6 weitere

Catheterization and Cardiovascular Interventions · 2024-05 · 103 (6) · 885-896

DOI: 10.1002/ccd.31020 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 02.04.2024. Verfasst von Koshiro Sakai und 17 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium. Hauptthemen laut MEDLINE: Thermodilution, Microcirculation, Predictive Value of Tests, Coronary Angiography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Two invasive methods are available to estimate microvascular resistance: bolus and continuous thermodilution. Comparative studies have revealed a lack of concordance between measurements of microvascular resistance obtained through these techniques.

Aims

This study aimed to examine the influence of vessel volume on bolus thermodilution measurements.

Methods

We prospectively included patients with angina with non‐obstructive coronary arteries (ANOCA) undergoing bolus and continuous thermodilution assessments. All patients underwent coronary CT angiography to extract vessel volume. Coronary microvascular dysfunction was defined as coronary flow reserve (CFR) < 2.0. Measurements of absolute microvascular resistance (in Woods units) and index of microvascular resistance (IMR) were compared before and after volumetric adjustment.

Results

Overall, 94 patients with ANOCA were included in this study. The mean age was 64.7 ± 10.8 years, 48% were female, and 19% had diabetes. The prevalence of CMD was 16% based on bolus thermodilution, while continuous thermodilution yielded a prevalence of 27% (Cohen's Kappa 0.44, 95% CI 0.23–0.65). There was no correlation in microvascular resistance between techniques ( r = 0.17, 95% CI −0.04 to 0.36, p = 0.104). The adjustment of IMR by vessel volume significantly increased the agreement with absolute microvascular resistance derived from continuous thermodilution ( r = 0.48, 95% CI 0.31–0.63, p < 0.001).

Conclusions

In patients with ANOCA, invasive methods based on coronary thermodilution yielded conflicting results for the assessment of CMD. Adjusting IMR with vessel volume improved the agreement with continuous thermodilution for the assessment of microvascular resistance. These findings strongly suggest the importance of considering vessel volume when interpreting bolus thermodilution assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThermodilutionMicrocirculationPredictive Value of TestsCoronary AngiographyCoronary VesselsVascular ResistanceCoronary CirculationComputed Tomography AngiographyCoronary Artery DiseaseHumansFemaleMaleMiddle AgedAgedProspective StudiesReproducibility of Results

Stichwörter der Autor:innen

absolute coronary flowbolus thermodilutioncoronary microvascular dysfunctionmicrovascular resistancevessel lumen volume

Autor:innen und Institutionen

  • Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium.
  • Department of Medicine, Division of Cardiology, Showa University School of Medicine, Tokyo, Japan.
  • Department of Prevention and Treatment of Emergency Conditions, L.T. Malaya Therapy National Institute NAMSU, Kharkiv, Ukraine.
  • Division of Clinical Pharmacology, Department of Pharmacology, Showa University, Tokyo, Japan.
  • Department of Cardiovascular Medicine, Gifu Heart Center, Gifu, Japan.
  • Department of Cardiology, Aichi Medical University, Aichi, Japan.

ORCID-Profile: Emanuele Gallinoro

Zitieren

APA

Sakai, K., Storozhenko, T., Mizukami, T., Ohashi, H., Bouisset, F., Tajima, A., van Hoe, L., Gallinoro, E., Botti, G., Mahendiran, T., Pardaens, S., Brouwers, S., Fawaz, S., Keeble, T. R., Davies, J. R., Sonck, J., De Bruyne, B., & Collet, C. (2024). Impact of vessel volume on thermodilution measurements in patients with coronary microvascular dysfunction. Catheterization and Cardiovascular Interventions, 103(6), 885-896. https://doi.org/10.1002/ccd.31020

Vancouver

Sakai K, Storozhenko T, Mizukami T, Ohashi H, Bouisset F, Tajima A, et al. Impact of vessel volume on thermodilution measurements in patients with coronary microvascular dysfunction. Catheterization and Cardiovascular Interventions. 2024;103(6):885-896. doi:10.1002/ccd.31020

BibTeX
@article{Sakai2024,
  author = {Sakai, Koshiro and Storozhenko, Tatyana and Mizukami, Takuya and Ohashi, Hirofumi and Bouisset, Frederic and Tajima, Atomu and van Hoe, Lieven and Gallinoro, Emanuele and Botti, Giulia and Mahendiran, Thabo and Pardaens, Sofie and Brouwers, Sofie and Fawaz, Samer and Keeble, Thomas R and Davies, John R and Sonck, Jeroen and De Bruyne, Bernard and Collet, Carlos},
  title = {Impact of vessel volume on thermodilution measurements in patients with coronary microvascular dysfunction},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  volume = {103},
  number = {6},
  pages = {885--896},
  doi = {10.1002/ccd.31020}
}
Kostenlos starten →