The everolimus eluting Synergy Megatron TM drug‐eluting stent platform: Early outcomes from the European Synergy Megatron TM Implanters' Registry
Catheterization and Cardiovascular Interventions · 2023
DOI: 10.1002/ccd.30902 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2023. Verfasst von Kalpa De Silva und 17 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Division, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Coronary Artery Disease, Percutaneous Coronary Intervention, Thrombosis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation.
Abstract (Originalsprache)
Background
The Synergy Megatron TM is an everolimus‐drug eluting stent that may offer advantages in the treatment of aorto‐ostial disease and large proximal vessels.
Aims
To report the short‐ to medium‐term clinical outcomes from the European Synergy Megatron TM Implanters' Registry.
Methods
This registry was an investigator‐initiated study conducted at 14 European centers. The primary outcome was target lesion failure (TLF), defined as the composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularisation.
Results
Five hundred seventy‐five patients underwent PCI with Megatron TM between 2019 and 2021. Patients were 69 ± 12 years old, 26% had diabetes mellitus, 24% had moderate‐severe left ventricular impairment and 59% presented with an acute coronary syndrome. 15% were deemed prohibitively high risk for surgical revascularisation. The target vessel involved the left main stem in 55%, the ostium of the RCA in 13% and was a true bifurcation (Medina 1,1,1) in 50%. At 1 year, TLF was observed in 40 patients, with 26 (65%) occurring within the first 30 days. The cumulative incidence of TLF was 4.5% at 30 days and 8.6% (95% CI 6.3–11.7) at 1 year. The incidence of stent thrombosis was 0.5% with no late stent thromboses. By multivariate analysis, the strongest independent predictors of TLF were severe left ventricular impairment (HR 3.43, 95% CI: 1.67–6.76, p < 0.001) and a target vessel involving the left main (HR 4.00 95% CI 1.81–10.15 p = 0.001).
Conclusions
Use of the Synergy Megatron TM everolimus eluting stent in a ‘real‐world’ setting shows favorable outcomes at 30 days and 1 year.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Cardiovascular Division, St Thomas' Hospital, Guy's and St Thomas' NHS Foundation Trust, London, UK.
- Coronary Research Group, British Heart Foundation Centre of Research Excellence, King's College London, London, UK.
- Cardiology Department, Salisbury District Hospital, Salisbury NHS Foundation Trust, Salisbury, UK.
- Cardio Respiratory Clinical Services Unit, Leeds General Infirmary, The Leeds Teaching Hospitals NHS Trust, Leeds, UK.
- Department of Cardiology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester, UK.
- Cardiology Department, University Hospital Galway, Galway, Ireland.
ORCID-Profile: Matthew E Li Kam Wa, Sinjini Biswas, James C Spratt, Jonathan A Mailey
Förderung
- British Heart Foundation
Zitieren
APA
De Silva, K., Li Kam Wa, M. E., Wells, T., Mozid, A., Ladwiniec, A., Hynes, B. G., Kotecha, A., Ratib, K., Biswas, S., Amabile, N., Deharo, P., McEntagart, M., Spratt, J. C., Digne, F., Hogg, M., Mailey, J. A., Walsh, S. J., & Kalra, S. S. (2023). The everolimus eluting Synergy Megatron TM drug‐eluting stent platform: Early outcomes from the European Synergy Megatron TM Implanters' Registry. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.30902
Vancouver
De Silva K, Li Kam Wa ME, Wells T, Mozid A, Ladwiniec A, Hynes BG, et al. The everolimus eluting Synergy Megatron TM drug‐eluting stent platform: Early outcomes from the European Synergy Megatron TM Implanters' Registry. Catheterization and Cardiovascular Interventions. 2023. doi:10.1002/ccd.30902
BibTeX
@article{DeSilva2023,
author = {De Silva, Kalpa and Li Kam Wa, Matthew E and Wells, Tim and Mozid, Abdul and Ladwiniec, Andrew and Hynes, Brian G and Kotecha, Ashish and Ratib, Karim and Biswas, Sinjini and Amabile, Nicolas and Deharo, Pierre and McEntagart, Margaret and Spratt, James C and Digne, Franck and Hogg, Meadhbh and Mailey, Jonathan A and Walsh, Simon J and Kalra, Sundeep S},
title = {The everolimus eluting Synergy Megatron TM drug‐eluting stent platform: Early outcomes from the European Synergy Megatron TM Implanters' Registry},
journal = {Catheterization and Cardiovascular Interventions},
year = {2023},
doi = {10.1002/ccd.30902}
}
EUVIMED