EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Serial quantitative angiographic study of target lumen enlargement after drug‐coated balloon angioplasty for native coronary artery disease

Katsumi Ueno iD, Norihiko Morita, Yoshinobu Kojima, Hiroshi Takahashi, Masayasu Esaki, Hiroki Kondo, Yu Ando, Mayu Yamada, Tai Kosokabe

Catheterization and Cardiovascular Interventions · 2023-03 · 101 (4) · 713-721

DOI: 10.1002/ccd.30598 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 25.02.2023. Verfasst von Katsumi Ueno und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Matsunami General Hospital, Kasamatsu, Japan. Hauptthemen laut MEDLINE: Coronary Artery Disease, Percutaneous Coronary Intervention, Angioplasty, Balloon, Coronary, Coronary Restenosis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Target lumen enlargement (TLE) or “late lumen enlargement” is often encountered after percutaneous coronary intervention (PCI) with drug‐coated balloons (DCB). To date, the prognosis of coronary arterial lesions with or without TLE has not been clearly elucidated.

Aims

This study aimed to assess the long‐term prognosis of coronary arterial lesions with or without TLE observed within 1 year (early TLE) after DCB angioplasty using serial quantitative angiographic follow‐up.

Methods

One hundred and ninety‐three consecutive patients (de novo coronary arterial lesions, 251) who underwent follow‐up angiography within 1 year after DCB angioplasty (early follow‐up, median: 6 months) were retrospectively evaluated. Of these, 97 patients (125 lesions) also underwent angiography more than 1 year after DCB angioplasty (late follow‐up, median: 37 months). TLE was defined as an increase in minimal lumen diameter (MLD) after PCI at each follow‐up.

Results

Early TLE was detected in 142 lesions (56.6%). Of these, 76 lesions were also evaluated at late follow‐up. TLE persisted even at late follow‐up in 67 of the 76 lesions (88.2%). An increase in MLD in early TLE (+) lesions was observed in the period between post‐PCI and early follow‐up (1.84 ± 0.06 vs. 2.12 ± 0.07 mm, p < 0.001) but not between early and late follow‐up (2.12 ± 0.07 vs. 2.16 ± 0.07 mm, p = 0.74). In contrast, 49 of 109 lesions without early TLE were evaluated at late follow‐up, of which 28 lesions (57.1%) showed TLE at late follow‐up. The MLD of early TLE (−) lesions ( n = 49) significantly increased from early (1.63 ± 0.061 mm) to late follow‐up (1.84 ± 0.06 mm) ( p < 0.001). No aneurysms were found in any of these cases.

Conclusion

Early TLE was observed in more than half of the lesions, with the majority remaining at late follow‐up. Alternatively, half of the lesions without early TLE showed late TLE, occurring biphasically after DCB angioplasty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery DiseasePercutaneous Coronary InterventionAngioplasty, Balloon, CoronaryCoronary RestenosisHumansRetrospective StudiesCoronary AngiographyTreatment OutcomeCoated Materials, Biocompatible

Stichwörter der Autor:innen

aneurysmcoronary interventiondrug-coated balloonlate lumen enlargementlate regressionprognosis

Substanzen

Coated Materials, Biocompatible

Autor:innen und Institutionen

  • Department of Cardiology, Matsunami General Hospital, Kasamatsu, Japan.
  • Department of Medical Statistics, Fujita Health University School of Medicine, Toyoake, Japan.

ORCID-Profile: Katsumi Ueno

Zitieren

APA

Ueno, K., Morita, N., Kojima, Y., Takahashi, H., Esaki, M., Kondo, H., Ando, Y., Yamada, M., & Kosokabe, T. (2023). Serial quantitative angiographic study of target lumen enlargement after drug‐coated balloon angioplasty for native coronary artery disease. Catheterization and Cardiovascular Interventions, 101(4), 713-721. https://doi.org/10.1002/ccd.30598

Vancouver

Ueno K, Morita N, Kojima Y, Takahashi H, Esaki M, Kondo H, et al. Serial quantitative angiographic study of target lumen enlargement after drug‐coated balloon angioplasty for native coronary artery disease. Catheterization and Cardiovascular Interventions. 2023;101(4):713-721. doi:10.1002/ccd.30598

BibTeX
@article{Ueno2023,
  author = {Ueno, Katsumi and Morita, Norihiko and Kojima, Yoshinobu and Takahashi, Hiroshi and Esaki, Masayasu and Kondo, Hiroki and Ando, Yu and Yamada, Mayu and Kosokabe, Tai},
  title = {Serial quantitative angiographic study of target lumen enlargement after drug‐coated balloon angioplasty for native coronary artery disease},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2023},
  volume = {101},
  number = {4},
  pages = {713--721},
  doi = {10.1002/ccd.30598}
}
Kostenlos starten →