EUVIMEDEUVIMED entdecken
Klinische StudieMultizentrische Studie

Intracoronary stenting without coumadin: One month results of a French multicenter study

M C Morice, G Zemour, E Benveniste, Y Biron, C Bourdonnec, R Faivre, J Fajadet, P Gaspard, B Glatt, P Joly

Catheterization and Cardiovascular Diagnosis · 1995-05 · 35 (1) · 1-7

DOI: 10.1002/ccd.1810350102 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Catheterization and Cardiovascular Diagnosis, online erschienen am 26.10.2005. Verfasst von M C Morice und 9 weiteren Autor:innen. Beteiligte Einrichtung: Centre Cardiologique du Nord, Saint-Denis, France. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Coronary, Stents. Die Arbeit wurde bisher 98-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In order to simplify post‐coronary stenting treatment and to obtain a lower rate of complications, especially in bailout situations, seven French institutions treated 246 stented patients with 0.25 g/day of ticlopidine, 0.1 g/day of IV aspirin, and 2 days of heparin followed by low‐molecular‐weight heparin for 1 month. Fifty percent of patients had a planned stenting procedure, and 50% had an unplanned procedure, including 29 (11.8%) in bailout situations. Subacute occlusion occurred in three (1.2%) patients (one death, two non‐Q‐wave infarctions). During the 1 month follow‐up period, another death was reported (non‐stent‐related), two elective coronary artery bypass grafts were performed, and three additional patients presented with non‐Q‐wave myocardial infarctions. Nine (3.7%) patients had a groin complication that required blood transfusion or surgical repair. These results suggest that while waiting for the technological advancements of stents, postprocedural treatment that includes a low dosage of ticlopidine, aspirin, and low‐molecular‐weight heparin is a very effective alternative to conventional poststenting therapy. © 1995 Wiley‐Liss, Inc.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Angioplasty, Balloon, CoronaryStentsAdultAgedAged, 80 and overAspirinCoronary DiseaseDrug Therapy, CombinationElectrocardiographyFemaleFollow-Up StudiesHeparin, Low-Molecular-WeightHumansMaleMiddle AgedProspective StudiesThrombosisTiclopidine

Substanzen

Heparin, Low-Molecular-WeightTiclopidineAspirin

Autor:innen und Institutionen

  • Centre Cardiologique du Nord, Saint-Denis, France.

Zitieren

APA

Morice, M. C., Zemour, G., Benveniste, E., Biron, Y., Bourdonnec, C., Faivre, R., Fajadet, J., Gaspard, P., Glatt, B., & Joly, P. (1995). Intracoronary stenting without coumadin: One month results of a French multicenter study. Catheterization and Cardiovascular Diagnosis, 35(1), 1-7. https://doi.org/10.1002/ccd.1810350102

Vancouver

Morice MC, Zemour G, Benveniste E, Biron Y, Bourdonnec C, Faivre R, et al. Intracoronary stenting without coumadin: One month results of a French multicenter study. Catheterization and Cardiovascular Diagnosis. 1995;35(1):1-7. doi:10.1002/ccd.1810350102

BibTeX
@article{Morice1995,
  author = {Morice, M C and Zemour, G and Benveniste, E and Biron, Y and Bourdonnec, C and Faivre, R and Fajadet, J and Gaspard, P and Glatt, B and Joly, P},
  title = {Intracoronary stenting without coumadin: One month results of a French multicenter study},
  journal = {Catheterization and Cardiovascular Diagnosis},
  year = {1995},
  volume = {35},
  number = {1},
  pages = {1--7},
  doi = {10.1002/ccd.1810350102}
}
Kostenlos starten →