EUVIMEDEUVIMED entdecken
Crossref

Effect of balloon aortic valvuloplasty on the dynamics of left ventricular ejection

J J Ferguson, H S Bush, E P Riuli

Catheterization and Cardiovascular Diagnosis · 1989-10 · 18 (2) · 73-78

DOI: 10.1002/ccd.1810180204 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Diagnosis, online erschienen am 25.10.2005. Verfasst von J J Ferguson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Section, Texas Heart Institute, St. Luke's Episcopal Hospital, Houston 77225. Hauptthemen laut MEDLINE: Catheterization. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To evaluate the effect of balloon aortic valvuloplasty on left ventricular ejection dynamics, simultaneous left ventricular and aortic pressures were obtained by use of a micromanometer catheter in nine patients before and after the procedure. Ejection times, stroke volumes (thermodilution), ejection rates, and pressure gradients were measured. For each parameter, ejection was then divided into two components: accelerative (onset systole to peak gradient) and decelerative (peak gradient to end systole). After valvuloplasty, there was (1) a decrease in overall ejection time and in mean and peak pressure gradients; (2) an increase in overall ejection rate; (3) no change in stroke volume or heart rate; (4) an increase in both accelerative and decelerative ejection rates and a decrease in the decelerative ejection time (expressed as a percentage of the R–R interval); and (5) a decrease in the time for the ejection of the final 25% of stroke volume ( P < 0.01) and time occupied by the final 25% of the gradient. Immediately following balloon aortic valuloplasty, there is a decrease in ejection time and in increase in ejection rate. Balloon aortic valvuloplasty has a significant effect on the dynamics of left ventricle ejection, with changes primarily expressed in late systole. By improving the mobility of calcified leaflets, balloon aortic valvuloplasty may reduce the forces opposing forward blood movement during the decelerative phase of ejection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CatheterizationAortic Valve StenosisCerebral VentriclesHumans

Autor:innen und Institutionen

  • Cardiology Section, Texas Heart Institute, St. Luke's Episcopal Hospital, Houston 77225.

Zitieren

APA

Ferguson, J. J., Bush, H. S., & Riuli, E. P. (1989). Effect of balloon aortic valvuloplasty on the dynamics of left ventricular ejection. Catheterization and Cardiovascular Diagnosis, 18(2), 73-78. https://doi.org/10.1002/ccd.1810180204

Vancouver

Ferguson JJ, Bush HS, Riuli EP. Effect of balloon aortic valvuloplasty on the dynamics of left ventricular ejection. Catheterization and Cardiovascular Diagnosis. 1989;18(2):73-78. doi:10.1002/ccd.1810180204

BibTeX
@article{Ferguson1989,
  author = {Ferguson, J J and Bush, H S and Riuli, E P},
  title = {Effect of balloon aortic valvuloplasty on the dynamics of left ventricular ejection},
  journal = {Catheterization and Cardiovascular Diagnosis},
  year = {1989},
  volume = {18},
  number = {2},
  pages = {73--78},
  doi = {10.1002/ccd.1810180204}
}