The accuracy and reliability of different midsagittal planes in the symmetry assessment using cone‐beam computed tomography
Clinical Anatomy · 2024
DOI: 10.1002/ca.24133 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Anatomy, 2024. Verfasst von Shaoyang Yu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China. Hauptthemen laut MEDLINE: Anatomic Landmarks, Cone-Beam Computed Tomography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Symmetry is an essential component of esthetic assessment. Accurate assessment of facial symmetry is critical to the treatment plan of orthognathic surgery and orthodontic treatment. However, there is no internationally accepted midsagittal plane (MSP) for orthodontists and orthognathic surgeons. The purpose of this study was to explore a clinically friendly MSP, which is more accurate and reliable than what is commonly used in symmetry assessment. Forty patients with symmetric craniofacial structures were analyzed on cone‐beam computed tomography (CBCT) scans. The CBCT data were exported to the Simplant Pro software to build four reference planes that were constructed by nasion (N), basion (Ba), sella (S), odontoid (Dent), or incisive foramen (IF). A total of 31 landmarks were located to determine which reference plane is the most optimal MSP by comparing the asymmetry index (AI). The mean value of AI showed a significant difference ( p < 0.05) among four reference planes. Also, the mean value of AI for all landmarks showed that Plane 2 (consisting of N, Ba, and IF) and Plane 4 (consisting of N, IF, and Dent) were more accurate and stable. In conclusion, the MSP consisting of N, Dent, and IF shows more accuracy and reliability than the other planes. Further, it is more clinically friendly because of its significant advantage in landmarking.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China.
- School of Stomatology, Qingdao University, Qingdao, China.
- Department of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Laboratory for Dental Materia…
ORCID-Profile: Shaoyang Yu
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yu, S., Zheng, Y., Dong, L., Huang, W., Wu, H., Zhang, Q., Yan, X., Wu, W., Lv, T., & Yuan, X. (2024). The accuracy and reliability of different midsagittal planes in the symmetry assessment using cone‐beam computed tomography. Clinical Anatomy. https://doi.org/10.1002/ca.24133
Vancouver
Yu S, Zheng Y, Dong L, Huang W, Wu H, Zhang Q, et al. The accuracy and reliability of different midsagittal planes in the symmetry assessment using cone‐beam computed tomography. Clinical Anatomy. 2024. doi:10.1002/ca.24133
BibTeX
@article{Yu2024,
author = {Yu, Shaoyang and Zheng, Yao and Dong, Lirong and Huang, Wenli and Wu, Haoting and Zhang, Qiang and Yan, Xiao and Wu, Wei and Lv, Tao and Yuan, Xiao},
title = {The accuracy and reliability of different midsagittal planes in the symmetry assessment using cone‐beam computed tomography},
journal = {Clinical Anatomy},
year = {2024},
doi = {10.1002/ca.24133}
}
EUVIMED