Kinetic and equilibrium analysis of electrochemical Aptasensing for real‐time detection of Staphylococcus aureus in food substances

Shokoufeh Soleimani, Tracy Ann Bruce-Tagoe, Michael K Danquah iD

Biotechnology Progress · 2026

DOI: 10.1002/btpr.70088 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biotechnology Progress, 2026. Verfasst von Shokoufeh Soleimani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Tennessee, Knoxville, Tennessee, USA. Hauptthemen laut MEDLINE: Staphylococcus aureus, Aptamers, Nucleotide, Electrochemical Techniques, Food Microbiology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 66 Literaturangaben. Gefördert von: National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real‐time detection of foodborne pathogens such as Staphylococcus aureus ( S. aureus ) is essential for ensuring food safety. In this study, we evaluate the performance of an electrochemical aptasensor developed from gold nanoparticles (AuNPs)‐immobilized screen‐printed carbon electrode for the detection of low concentrations of S. aureus in chicken extract media. Using cyclic voltammetry (CV), the dynamic interaction between the aptamer‐modified electrode and S. aureus was monitored across four bacterial concentrations of 1, 5, 10, and 20 colony‐forming units per milliliter (CFU/mL) at 35‐min intervals over 350 min. The aptasensor demonstrated a concentration‐dependent response with increasingly lower maximum CV signals and faster time to equilibrium as CFU increased. Real‐time kinetic and equilibrium parameters were extracted to understand the binding behavior of the pathogen to the electrode surface. Critical parameters such as the kinetic rate constant ( k ) of 0.0274 min −1 and equilibrium dissociation constants () of 7.35 CFU/mL, were derived from the CV signals. Langmuir isotherm modeling yielded a maximum binding capacity () of 33.55 μA. In addition, a Hill coefficient (n H ) of 0.65 was obtained, which indicates a slightly negative cooperativity. These findings demonstrate the capability of the aptasensor for real‐time detection of S. aureus , offering a robust framework for field‐deployable pathogen monitoring in food matrices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Staphylococcus aureusAptamers, NucleotideElectrochemical TechniquesFood MicrobiologyBiosensing TechniquesKineticsGoldMetal NanoparticlesAnimalsElectrodesChickens

Stichwörter der Autor:innen

Staphylococcus aureusbinding kineticscyclic voltammetryelectrochemical aptasensorreal‐time detection

Substanzen

Aptamers, NucleotideGold

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of Tennessee, Knoxville, Tennessee, USA.
  • Department of Chemical and Biomolecular Engineering, University of Tennessee, Knoxville, Tennessee, USA.

ORCID-Profile: Michael K Danquah

Förderung

  • National Science Foundation

Zitieren

APA

Soleimani, S., Bruce-Tagoe, T. A., & Danquah, M. K. (2026). Kinetic and equilibrium analysis of electrochemical Aptasensing for real‐time detection of Staphylococcus aureus in food substances. Biotechnology Progress. https://doi.org/10.1002/btpr.70088

Vancouver

Soleimani S, Bruce-Tagoe TA, Danquah MK. Kinetic and equilibrium analysis of electrochemical Aptasensing for real‐time detection of Staphylococcus aureus in food substances. Biotechnology Progress. 2026. doi:10.1002/btpr.70088

BibTeX
@article{Soleimani2026,
  author = {Soleimani, Shokoufeh and Bruce-Tagoe, Tracy Ann and Danquah, Michael K},
  title = {Kinetic and equilibrium analysis of electrochemical Aptasensing for real‐time detection of Staphylococcus aureus in food substances},
  journal = {Biotechnology Progress},
  year = {2026},
  doi = {10.1002/btpr.70088}
}
Kostenlos starten →