Effect of flux and shear rate on E. coli recovery in tangential flow filtration through a single hollow fiber
Biotechnology Progress · 2024-05 · 40 (3)
DOI: 10.1002/btpr.3432 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biotechnology Progress, online erschienen am 08.02.2024. Verfasst von Jessica Zuponcic und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, Indiana, USA. Hauptthemen laut MEDLINE: Escherichia coli, Filtration, Membranes, Artificial. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FDA HHS, U.S. Department of Agriculture, Purdue University.
Abstract (Originalsprache)
Pathogenic bacteria which enter a viable but non‐culturable (VBNC) state impede efforts to reach detectable concentrations required for PCR methods. This motivated a strategy for tangential flow filtration to concentrate bacteria in aqueous samples while maintaining the bacteria in a viable state, maximizing their recovery and achieving high fluxes through a single hollow fiber membrane. Filtrations were carried out for green fluorescent protein (GFP) E. coli at high shear rates (up to 27,000 sec −1 ) through 0.2 μm cut‐off polyethersulfone (PES) microfilter membranes or 50 kDa polysulfone (PS) ultrafilter membranes. High shear minimized bacterial attachment on membrane surfaces, which would otherwise occur due to forced convection of the particles to the membrane surface at high flux conditions. Single fiber filter modules were constructed to facilitate concentration of Escherichia coli at fluxes ranging from 55 to 4500 L m −2 h −1 . The effect of high shear rates on bacterial viability was found to be minimal with bacterial losses during filtration caused principally by their accumulation on the membrane surface. Recoveries of 90% were achievable at high shear rates when the average flux was ≤300 L m −2 h −1 . This corresponded to a 3‐h filtration time for a 225 mL sample through a single hollow fiber. Detectable bacteria concentrations of 1800 colony‐forming unit (CFU)/mL were achieved for starting concentrations of 140 CFU/mL.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, Indiana, USA.
- Laboratory of Renewable Resources Engineering, Purdue University, West Lafayette, Indiana, USA.
- Department of Environmental and Occupational Health, Indiana University, Bloomington, Indiana, USA.
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
ORCID-Profile: Michael R Ladisch
Förderung
- FDA HHS
- U.S. Department of Agriculture
- Purdue University
- Food and Drug Administration
Zitieren
APA
Zuponcic, J., Cunha, F., Springer, G., Ximenes, E., & Ladisch, M. R. (2024). Effect of flux and shear rate on E. coli recovery in tangential flow filtration through a single hollow fiber. Biotechnology Progress, 40(3). https://doi.org/10.1002/btpr.3432
Vancouver
Zuponcic J, Cunha F, Springer G, Ximenes E, Ladisch MR. Effect of flux and shear rate on E. coli recovery in tangential flow filtration through a single hollow fiber. Biotechnology Progress. 2024;40(3). doi:10.1002/btpr.3432
BibTeX
@article{Zuponcic2024,
author = {Zuponcic, Jessica and Cunha, Fernanda and Springer, Grant and Ximenes, Eduardo and Ladisch, Michael R},
title = {Effect of flux and shear rate on E. coli recovery in tangential flow filtration through a single hollow fiber},
journal = {Biotechnology Progress},
year = {2024},
volume = {40},
number = {3},
doi = {10.1002/btpr.3432}
}
EUVIMED