Fachartikel in der Zeitschrift Biotechnology Progress, 2024. Verfasst von Mukesh Mayani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Genomic Medicine Unit CMC, Global CMC Development, Waltham, Massachusetts, USA. Hauptthemen laut MEDLINE: Lentivirus, Filtration. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Depth filtration significantly impacts efficiency of lentiviral (LV) vector purification process. However, it is often deprioritized in the overall scope of viral vector manufacturing process optimization. The demand for LV vectors has increased with the rise in disease indications, making it crucial to improve current manufacturing processes. Upstream bioreactor process intensification has enabled cell densities of over 10 7 viable cells/mL, creating challenges for harvest unit operations. The larger size of LV vectors and their physiochemical similarity to host cell‐DNA (HC‐DNA) and poor clarification performance causes significant challenges for the subsequent chromatography‐based purifications. As a result, a robust and scalable harvest of LV process is needed, especially for LV in vivo therapeutic quality needs. In this study, we systematically evaluated the overlooked yet important issue of depth filtration systems to improve enveloped LV functional vector recovery. We found that an established depth filtration system in process A that provided 94% ( n = 6) LV functional recovery could not be translated to intensified Process B cell culture. Hence, the depth filtration process became a bottleneck for the purification performance in an intensified process. We demonstrated an improvement in LV functional vector recovery from 34% to 82% via filter train optimization for an intensified suspension cell culture system (>10 7 cells/mL with higher titer), while still maintaining a loading throughput of ≥82 L/m 2 and turbidity ≤20 NTU. It was demonstrated that the two or three‐stage depth filtration scheme is scalable and more suitable for high cell density culture for large scale for LV manufacturing process.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Genomic Medicine Unit CMC, Global CMC Development, Waltham, Massachusetts, USA.
- Process and Analytical Development (PAD), Gene Therapy Franchise, National Resilience Inc., Waltham, Massachusetts, USA.
- MilliporeSigma, Burlington, Massachusetts, USA.
ORCID-Profile: Mukesh Mayani
Zitieren
APA
Mayani, M., Nellimarla, S., Mangalathillam, R., Rao, H., Patarroyo-White, S., Ma, J., & Figueroa, B. (2024). Depth filtration for clarification of intensified lentiviral vector suspension cell culture. Biotechnology Progress. https://doi.org/10.1002/btpr.3409
Vancouver
Mayani M, Nellimarla S, Mangalathillam R, Rao H, Patarroyo-White S, Ma J, et al. Depth filtration for clarification of intensified lentiviral vector suspension cell culture. Biotechnology Progress. 2024. doi:10.1002/btpr.3409
BibTeX
@article{Mayani2024,
author = {Mayani, Mukesh and Nellimarla, Srinivas and Mangalathillam, Ratish and Rao, Hema and Patarroyo-White, Susannah and Ma, Junfen and Figueroa, Bruno},
title = {Depth filtration for clarification of intensified lentiviral vector suspension cell culture},
journal = {Biotechnology Progress},
year = {2024},
doi = {10.1002/btpr.3409}
}
EUVIMED