EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Methodology for computational assessment of hemolysis in under‐occlusive roller pumps operated at clinically relevant conditions

Jiří Kohút iD, Jiří Jagoš, Pavel Suk iD, Martin Formánek iD, Jiří Burša iD

Bioengineering & Translational Medicine · 10.11.2026

DOI: 10.1002/btm2.70191 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering & Translational Medicine, online erschienen am 10.11.2026. Verfasst von Jiří Kohút und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mechanical Engineering Brno University of Technology Brno Czech Republic. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hemolysis remains a major concern in clinical procedures involving extracorporeal blood circuits, with the blood delivery pump often being its considerable source. This study focuses on roller pumps, which—alongside centrifugal pumps—are the main types used in clinical practice. The objective is to establish a comprehensive methodology for the computational evaluation of hemolysis in under‐occlusive roller pumps, which, compared to fully occlusive operation, have the potential to reduce hemolysis while maintaining sufficient flow performance. The methodology employs transient 2D CFD simulations with a dynamic mesh, while hemolysis is evaluated using a shear‐induced hemolysis model. The governing equations are solved using the transitional low‐ Re SST turbulence model with appropriate prism‐layer refinement at the wall, adhering to values lower than 1, which is essential for accurate hemolysis estimation. In contrast to existing studies, the simulations are complemented by experimental measurements from an in vitro circuit operated under clinically relevant settings, providing realistic boundary conditions and validation support. The core component of the circuit is an in‐house roller pump that enables precise setting and control of the under‐occlusion degree. The proposed methodology enables to estimate and compare hemolysis across five under‐occlusion settings with progressively increasing gap size, each characterized by the corresponding reduction in flow rate. The results indicate that hemolysis levels remain comparable across under‐occlusive settings with flow reductions of up to 37%, with no substantial decrease observed over this range. A more pronounced reduction in hemolysis is observed only at higher degrees of under‐occlusion, corresponding to 50% and 63% flow reductions, which, however, result in clinically unacceptable losses in flow performance. Thus, the simulations suggest that the tightest under‐occlusive setting with 10% flow reduction provides the most favorable balance between hemolysis and flow performance.

Schlagwörter

Stichwörter der Autor:innen

CFD simulationsextracorporeal circuitshemolysisroller pumpsshear stressunder‐occlusion

Autor:innen und Institutionen

  • Faculty of Mechanical Engineering Brno University of Technology Brno Czech Republic.
  • Department of Anaesthesia and Intensive Care St. Anne's University Hospital and Masaryk University Brno Czech Republic.

ORCID-Profile: Jiří Kohút, Pavel Suk, Martin Formánek, Jiří Burša

Zitieren

APA

Kohút, J., Jagoš, J., Suk, P., Formánek, M., & Burša, J. (2026). Methodology for computational assessment of hemolysis in under‐occlusive roller pumps operated at clinically relevant conditions. Bioengineering & Translational Medicine. https://doi.org/10.1002/btm2.70191

Vancouver

Kohút J, Jagoš J, Suk P, Formánek M, Burša J. Methodology for computational assessment of hemolysis in under‐occlusive roller pumps operated at clinically relevant conditions. Bioengineering & Translational Medicine. 2026. doi:10.1002/btm2.70191

BibTeX
@article{Koht2026,
  author = {Kohút, Jiří and Jagoš, Jiří and Suk, Pavel and Formánek, Martin and Burša, Jiří},
  title = {Methodology for computational assessment of hemolysis in under‐occlusive roller pumps operated at clinically relevant conditions},
  journal = {Bioengineering & Translational Medicine},
  year = {2026},
  doi = {10.1002/btm2.70191}
}
Kostenlos starten →