The hanging‐heart chip: A portable microfluidic device for high‐throughput generation of contractile embryonic stem cell‐derived cardiac spheroids
Bioengineering & Translational Medicine · 2025-05 · 10 (3)
DOI: 10.1002/btm2.10726 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioengineering & Translational Medicine, online erschienen am 08.10.2024. Verfasst von Pei-Tzu Lai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering and Nanomedicine National Health Research Institutes Miaoli County Taiwan, ROC. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.
Abstract (Originalsprache)
Stem cell‐derived cardiac spheroids are promising models for cardiac research and drug testing. However, generating contracting cardiac spheroids remains challenging because of the laborious experimental procedure. Here, we present a microfluidic hanging‐heart chip (HH‐chip) that uses a microchannel and flow‐driven system to facilitate cell loading and culture medium replacement operations to reduce the laborious manual handling involved in the generation of a large quantity of cardiac spheroids. The effectiveness of the HH‐chip was demonstrated by simultaneously forming 50 mouse embryonic stem cell‐derived embryonic bodies, which sequentially differentiated into 90% beating cardiac spheroids within 15 days of culture on the chip. A comparison of our HH‐chip method with traditional hanging‐drop and low‐attachment plate methods revealed that the HH‐chip could generate higher contracting proportions of cardiac spheroids with higher expression of cardiac markers. Additionally, we verified that the contraction frequencies of the cardiac spheroids generated from the HH‐chip were sensitive to cardiotoxic drugs. Overall, our results suggest that the microfluidic hanging drop chip‐based approach is a high‐throughput and highly efficient method for generating contracting mouse embryonic stem cell‐derived cardiac spheroids for cardiac toxicity and drug testing applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Biomedical Engineering and Nanomedicine National Health Research Institutes Miaoli County Taiwan, ROC.
- Institute of Nanoengineering and Microsystems National Tsing Hua University Hsinchu Taiwan.
- Ph.D. Program in Tissue Engineering and Regenerative Medicine National Chung Hsing University Taichung Taiwan.
ORCID-Profile: Cheng-Kun He, Chi-Han Li
Förderung
- National Science and Technology Council
Zitieren
APA
Lai, P. T., He, C. K., Li, C. H., Matahum, J., Tang, C. Y., & Hsu, C. H. (2025). The hanging‐heart chip: A portable microfluidic device for high‐throughput generation of contractile embryonic stem cell‐derived cardiac spheroids. Bioengineering & Translational Medicine, 10(3). https://doi.org/10.1002/btm2.10726
Vancouver
Lai PT, He CK, Li CH, Matahum J, Tang CY, Hsu CH. The hanging‐heart chip: A portable microfluidic device for high‐throughput generation of contractile embryonic stem cell‐derived cardiac spheroids. Bioengineering & Translational Medicine. 2025;10(3). doi:10.1002/btm2.10726
BibTeX
@article{Lai2025,
author = {Lai, Pei-Tzu and He, Cheng-Kun and Li, Chi-Han and Matahum, Jefunnie and Tang, Chia-Yu and Hsu, Chia-Hsien},
title = {The hanging‐heart chip: A portable microfluidic device for high‐throughput generation of contractile embryonic stem cell‐derived cardiac spheroids},
journal = {Bioengineering & Translational Medicine},
year = {2025},
volume = {10},
number = {3},
doi = {10.1002/btm2.10726}
}
EUVIMED