EUVIMEDEUVIMED entdecken
Open Access

Determination of Hecogenin in Mouse Blood by UPLC–MS/MS and Applied to a Pharmacokinetic Study

Yujie Hu, Lei Zhu iD, Xueying Xiang, Tao Zou, Congcong Wen iD, Qiong Duan

Biomedical Chromatography · 2026

DOI: 10.1002/bmc.70618 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2026. Verfasst von Yujie Hu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Guizhou Fanglue Economic Information Co. Ltd, Guiyang, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hecogenin, a steroidal sapogenin from agave plants, exhibits anti‐inflammatory, anti‐tumor, gastroprotective, and diuretic activities. A sensitive ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method was developed and validated for quantifying hecogenin in mouse whole blood using swertisin as internal standard. Protein precipitation with acetonitrile enabled simple pretreatment of only 20‐μL blood samples. Separation was achieved on a BEH C18 column with gradient elution, and detection was performed via multiple reaction monitoring in positive electrospray ionization mode. The assay was linear over 1–2000 ng/mL ( r = 0.9988), with a lower limit of quantification of 1 ng/mL. Intra‐ and interday precision (RSD) were below 11% and 12%, respectively, and accuracy ranged from 93.2% to 110.4%. Matrix effects were negligible, and extraction recovery was 87.5%–91.2%. The validated method was applied to a pharmacokinetic study in male ICR mice following intravenous (5 mg/kg) and oral (10, 20 mg/kg) administration. Noncompartmental analysis revealed low oral absolute bioavailability (10.8%–12.4%).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryAnimalsMaleMiceReproducibility of ResultsChromatography, High Pressure LiquidMice, Inbred ICRLinear ModelsLimit of DetectionSensitivity and SpecificitySapogenins

Stichwörter der Autor:innen

UPLC‐MS/MSbioavailabilityhecogeninmethod validationmouse bloodpharmacokineticsprotein precipitationsteroidal sapogenin

Substanzen

hecogeninSapogenins

Autor:innen und Institutionen

  • Guizhou Fanglue Economic Information Co. Ltd, Guiyang, China.
  • Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, China.
  • Department of Pharmacy, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, China.

ORCID-Profile: Lei Zhu, Congcong Wen

Zitieren

APA

Hu, Y., Zhu, L., Xiang, X., Zou, T., Wen, C., & Duan, Q. (2026). Determination of Hecogenin in Mouse Blood by UPLC–MS/MS and Applied to a Pharmacokinetic Study. Biomedical Chromatography. https://doi.org/10.1002/bmc.70618

Vancouver

Hu Y, Zhu L, Xiang X, Zou T, Wen C, Duan Q. Determination of Hecogenin in Mouse Blood by UPLC–MS/MS and Applied to a Pharmacokinetic Study. Biomedical Chromatography. 2026. doi:10.1002/bmc.70618

BibTeX
@article{Hu2026,
  author = {Hu, Yujie and Zhu, Lei and Xiang, Xueying and Zou, Tao and Wen, Congcong and Duan, Qiong},
  title = {Determination of Hecogenin in Mouse Blood by UPLC–MS/MS and Applied to a Pharmacokinetic Study},
  journal = {Biomedical Chromatography},
  year = {2026},
  doi = {10.1002/bmc.70618}
}
Kostenlos starten →