Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 06.08.2026. Verfasst von Subbarao Jhampani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Chemistry, Chebrolu Hanumaiah Institute of Pharmaceutical Sciences, Chowdavaram, Andhra Pradesh, India. Hauptthemen laut MEDLINE: Aminophenols, Quinolones, Benzodioxoles, Aminopyridines. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cystic fibrosis, a genetic disorder caused by mutations in the CFTR gene, is commonly treated using combination therapy with IVA and LUMA. Accurate quantification of these drugs in human plasma is essential for therapeutic monitoring; however, conventional analytical methods often lack sufficient sensitivity and robustness. In this study, a QbD‐based RP‐UPLC method was developed and validated for the simultaneous estimation of IVA and LUMA in human plasma. The primary objective was to achieve efficient separation of analytes from plasma interferences with reduced run time and consistent analytical performance. Chromatographic separation was carried out using a Waters Acquity UPLC system equipped with a CSH C18 column (100 mm × 2.1 mm, 1.8 μm). Method optimization was performed using a Central Composite Design model. The mobile phase is 0.01 N ammonium acetate and acetonitrile (60:40, v/v) at a flow rate of 0.3 mL/min, with the column maintained at 30°C. EMT was used as the internal standard, and detection was conducted at 260 nm. The retention times were 1.45, 1.77, and 1.99 min for EMT, IVA, and LUMA, respectively. The method is reliable, rapid and selective, exhibiting excellent linearity, precision, and accuracy, complying with USFDA guidelines.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AminophenolsQuinolonesBenzodioxolesAminopyridinesChromatography, Reverse-PhaseHumansChromatography, High Pressure LiquidReproducibility of ResultsLimit of DetectionLinear Models

Stichwörter der Autor:innen

IVA and LUMAbioanalysisinternal standardquality by designreverse‐phase ultra performance liquid chromatography

Substanzen

AminophenolsQuinolonesBenzodioxolesAminopyridineslumacaftorivacaftor

Autor:innen und Institutionen

  • Department of Pharmaceutical Chemistry, Chebrolu Hanumaiah Institute of Pharmaceutical Sciences, Chowdavaram, Andhra Pradesh, India.
  • Department of Pharmaceutical Analysis, University College of Pharmaceutical Sciences Acharya Nagarjuna University, Guntur, Andhra Pradesh, India.
  • Department of Pharmaceutics, Chebrolu Hanumaiah Institute of Pharmaceutical Sciences, Chowdavaram, Andhra Pradesh, India.

ORCID-Profile: Subbarao Jhampani, Rayini Venkata Sai Mounica, Suryadevara Vidhyadhara

Zitieren

APA

Jhampani, S., Mounica, R. V. S., & Vidhyadhara, S. (2026). An Integrated Quality by Design RP‐UPLC Method for Lumacaftor and Ivacaftor in Human Plasma. Biomedical Chromatography, 40(9). https://doi.org/10.1002/bmc.70587

Vancouver

Jhampani S, Mounica RVS, Vidhyadhara S. An Integrated Quality by Design RP‐UPLC Method for Lumacaftor and Ivacaftor in Human Plasma. Biomedical Chromatography. 2026;40(9). doi:10.1002/bmc.70587

BibTeX
@article{Jhampani2026,
  author = {Jhampani, Subbarao and Mounica, Rayini Venkata Sai and Vidhyadhara, Suryadevara},
  title = {An Integrated Quality by Design RP‐UPLC Method for Lumacaftor and Ivacaftor in Human Plasma},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {9},
  doi = {10.1002/bmc.70587}
}
Kostenlos starten →