EUVIMEDEUVIMED entdecken
Open Access

AQbD‐Based Development and Optimization of a Stability‐Indicating RP‐HPLC Method for Imeglimin With Integration of Lean Six Sigma Principles

Vidhya K Bhusari iD, Samiksha Ghorpade, Kamini Sethy

Biomedical Chromatography · 2026-09 · 40 (9)

DOI: 10.1002/bmc.70563 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 24.07.2026. Verfasst von Vidhya K Bhusari und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Chemistry, KJ'S Educational Institute, Trinity College of Pharmacy, Pune, Maharashtra, India. Hauptthemen laut MEDLINE: Chromatography, Reverse-Phase. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An accurate and green RP‐HPLC stability indicating method has been developed for estimation of Imeglimin with an AQbD approach. Method optimization was done based on Box–Behnken design by changing factors like mobile phase, pH, and flow rate for optimum resolution and retention time. Lean Six Sigma (DMAIC) and statistical process control techniques ensured the consistency of the method. Water–methanol in the ratio of 65:35 (v/v) adjusted to pH 4.0 was used as the mobile phase at a flow rate of 0.8 mL/min, having an approximate retention time of 3.7 min. Method validation was performed as per the ICH guidelines, and the method exhibited a high correlation coefficient ( R 2 = 0.9994), low %RSD (< 2%), and good accuracy (99.45%–100.35%). LOD and LOQ were found to be 1.04 and 3.15 μg/mL, respectively. The results of forced degradation experiments showed significant degradation in the presence of alkaline, oxidative, and thermal stress conditions, whereas Imeglimin remained stable under photolytic stress conditions. HR‐MS and FTIR studies indicated that N‐dealkylation and N‐demethylation were possible degradation pathways. The greenness assessment of the developed method was carried out using AGREE, GAPI, BAGI, and CLICK indices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chromatography, Reverse-PhaseChromatography, High Pressure LiquidReproducibility of ResultsDrug StabilityLimit of DetectionLinear Models

Stichwörter der Autor:innen

AGREEBAGIBox–Behnken designCLICK analytical chemistry indexGAPIImegliminanalytical quality by designhigh‐resolution mass spectrometrystability‐indicating RP‐HPLCvalidation

Autor:innen und Institutionen

  • Department of Pharmaceutical Chemistry, KJ'S Educational Institute, Trinity College of Pharmacy, Pune, Maharashtra, India.
  • Department of Pharmaceutical Chemistry, Smt. Kashibai Navale College of Pharmacy, Savitribai Phule Pune University, Pune, Maharashtra, India.
  • Department of Pharmaceutical Chemistry, School of Pharmacy and Life Sciences, Centurion University of Technology and Management, Odisha, India.

ORCID-Profile: Vidhya K Bhusari

Zitieren

APA

Bhusari, V. K., Ghorpade, S., & Sethy, K. (2026). AQbD‐Based Development and Optimization of a Stability‐Indicating RP‐HPLC Method for Imeglimin With Integration of Lean Six Sigma Principles. Biomedical Chromatography, 40(9). https://doi.org/10.1002/bmc.70563

Vancouver

Bhusari VK, Ghorpade S, Sethy K. AQbD‐Based Development and Optimization of a Stability‐Indicating RP‐HPLC Method for Imeglimin With Integration of Lean Six Sigma Principles. Biomedical Chromatography. 2026;40(9). doi:10.1002/bmc.70563

BibTeX
@article{Bhusari2026,
  author = {Bhusari, Vidhya K and Ghorpade, Samiksha and Sethy, Kamini},
  title = {AQbD‐Based Development and Optimization of a Stability‐Indicating RP‐HPLC Method for Imeglimin With Integration of Lean Six Sigma Principles},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {9},
  doi = {10.1002/bmc.70563}
}
Kostenlos starten →