Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 06.05.2026. Verfasst von Satyanarayana Reddy Jaggavarapu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Koneru Lakshmaiah Education Foundation, Guntur, Andhra Pradesh, India. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A comprehensive, stability‐indicating, and environmentally sustainable analytical strategy was developed for the impurity and degradation profiling of iptacopan. Optimum separation was achieved on a Hypersil BDS C18 (250 × 4.6 mm, 5 μm) column using 0.8‐mL/min isocratic flow of 10‐mM ammonium acetate buffer (pH 4.5) and ethanol (60:40, v/v) with 234‐nm UV detection. The method produced excellent linearity ( r 2 ≥ 0.9995), precision (%RSD ≤ 0.75), accuracy (98.32%–100.26%), and robustness. Forced degradation studies generated four distinct degradation products (DPs) under acidic and oxidative stress, characterized by LC–MS/MS. DP 3 showed a +30‐Da mass increase (m/z 453.4996), consistent with an indole‐carboxylic acid analogue, whereas DP 1 (m/z 439.4730) exhibited a −14‐Da shift, indicating demethylation. DP 2 displayed a −42‐Da difference (m/z 381.4369) due to dealkylation, and DP 4 showed a +14‐Da shift (m/z 437.5002), corresponding to a linker ketone analogue. In silico toxicity assessment suggested moderate toxicity for most DPs, with DP 4 showing a comparatively favorable profile. Greenness and whiteness evaluation using AGREE (0.82), AGREE‐Prep (0.81), GAPI (E‐factor = 10), and RGB‐12 (78.0%) confirmed excellent environmental and practical performance. The method provides a robust and sustainable platform for quality control and stability assessment of iptacopan.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryChromatography, High Pressure LiquidReproducibility of ResultsDrug StabilityLinear ModelsAnimalsLimit of DetectionDrug ContaminationComputer SimulationBenzoatesIndolesPiperidines

Stichwörter der Autor:innen

degradation productsiptacopanmethod greennessmethod whitenessprocess‐related impurities

Substanzen

iptacopanBenzoatesIndolesPiperidines

Autor:innen und Institutionen

  • Department of Chemistry, Koneru Lakshmaiah Education Foundation, Guntur, Andhra Pradesh, India.
  • Department of Chemistry, RTM Nagpur University, Nagpur, Maharashtra, India.

ORCID-Profile: Ajmal R Bhat, Venkateswara Rao Anna

Zitieren

APA

Jaggavarapu, S. R., Bhat, A. R., & Anna, V. R. (2026). Comprehensive Impurity and Degradation Profiling of Iptacopan Using a White–Green Stability‐Indicating HPLC Method Coupled With LC–MS/MS and In Silico Toxicity Evaluation. Biomedical Chromatography, 40(6). https://doi.org/10.1002/bmc.70483

Vancouver

Jaggavarapu SR, Bhat AR, Anna VR. Comprehensive Impurity and Degradation Profiling of Iptacopan Using a White–Green Stability‐Indicating HPLC Method Coupled With LC–MS/MS and In Silico Toxicity Evaluation. Biomedical Chromatography. 2026;40(6). doi:10.1002/bmc.70483

BibTeX
@article{Jaggavarapu2026,
  author = {Jaggavarapu, Satyanarayana Reddy and Bhat, Ajmal R and Anna, Venkateswara Rao},
  title = {Comprehensive Impurity and Degradation Profiling of Iptacopan Using a White–Green Stability‐Indicating HPLC Method Coupled With LC–MS/MS and In Silico Toxicity Evaluation},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {6},
  doi = {10.1002/bmc.70483}
}
Kostenlos starten →